Operation Manual
Specifications
No. of light beams
Typical response time
Max. response time
Operating range
Power supply voltage
Power consumption
Fuse
Relay output
Temperature range (operation resp. inventory)
Max. door speed
Cable life time (if correctly installed)
Vibration and shock resistance
Declaration of conformity
CEDES AG declares conformity in sole responsibility, that the
Light curtain cegard
Products
EC directives
EMC 89 / 336 / EC, amended 92 / 31 / EC and
Low Voltage 73 / 23 / EC.
CSA
Certificate Number: LR 109459-2, 14 January 1998
Standards
EN 50'081-1, -2
EN 50082-1, -2
EN12015
EN12016
Test reports
No. 11'663, montena emc sa, CH-1700 Fribourg
TB980610.DOC and EMV9804.DOC, CEDES AG, CH-7302 Landquart
CSA certificate of complianceNo. LR 109459-2
Use
Use is only permitted after thorough checks are carried out to ensure that the equipment
into which these products are built into, meet the requirements of the regulations and di-
rectives relevant to that equipment.
Place and Date
Landquart, 30 September 1999
Signed
Beat De Coi, Managing Director
© CEDES
All manuals and user guides at all-guides.com
TM
cegard
Max-74
max. 74
75 ms
150 ms
0 ... 5 m
102 333
15 ... 25 VAC
15 ... 30 VDC
150 mA@24 VDC
250VAC / 8 A, 125V DC / 0.5 A, 30 VDC / 8 A,
TM
/Max (all types including Progard
EMC emission
EMC immunity
EMC emission elevators and escalators
EMC immunity elevators and escalators
part no. 101 232
/Max
Max-114
max. 114
90 ms
180 ms
0 ... 5 m
101 231 / 102 335
17 ... 240 VAC/DC
5 VA@115/230 VAC/50 mA@24 VDC
-
min. 5 VDC / 10 mA
-20 ° ... +65 °C resp. -30° ... +85 °C
1.6 m/s
20 millions of door movements
IEC 68-2-6
®
L LVH 24sd)
CEDES
Max-154
max. 154
100 ms
200 ms
0 ... 5 m
6.3AT
15