INSTALLATION LOCATIONS TO AVOID

1. Near equipment and/or areas where smoke/vapor regularly occurs
(kitchens, fireplace rooms, boiler rooms, and similar locations). Use special
smoke detectors for these areas.
2. Areas of high humidity, such as bathrooms or laundry rooms. At least 3 m
away from these areas.
3. Near vents and vents for heating and cooling. At least 1 m away from these
areas. The air could blow smoke away from the smoke detector and stop
an alarm or even cause a false alarm.
4. In rooms where the temperature could drop below 5 °C or rise above
40 °C.
5. In dusty or dirty areas, particles will interfere with the operation of the
smoke detector. False alarm could be triggered.
6. Installation (screwing) on plaster containing asbestos may only be carried
out using low-emission processes

INSTALLATION

Note: The bracket or device will not close without the battery being
properly installed. This is a legal requirement and is for your safety.
1. Remove the bracket from the alarm body.
2. Hold the bracket in the installation position and mark the bracket
installation holes with a pencil.
3. Drill two holes for the dowels.
4. Attach the bracket to the dowels and tighten the screws (see installation
diagram).
5. Attach the alarm to the bracket and turn the alarm body clockwise until it
locks into the bracket.
6. Press the test button for at least 5 seconds to test the device. The
alarm will sound: 3 beeps - 1.5 second pause. If no sound is heard, this
indicates a faulty alarm. You may find a solution in this manual under
„Troubleshooting.
7.
If you have further questions about the installation, contact your dealer.
Note: To avoid injury, this unit must be securely fastened to the ceiling
according to the installation instructions.