For power supply: 400V 50Hz
Distribution box (Customer prepare)
Power Supply
400V 50Hz
Earthing
Note: 1)
Must be hard wired, plug is not allowed.
2) The swimming pool heat pump must be earthed well.

4. References for protecting devices and cable specification

MODEL
Breaker
Rated Residual Action Current
Fuse (A)
Power Cord (mm
Signal cable (mm
Above data is subject to modification without notice.
Note: The above data is adapted to power cord ≤ 10m. If power cord is>10m, wire diameter must be increased.
The signal cable can be extended to 50m maximumly.
Fuse
Breaker
Rated Current A
mA
2
)
2
)
Swimming Pool Heat Pump Wiring Board
Power Cord
Skyline 75
Skyline 95
12
14.5
30
30
12
14.5
3 x 2.5
3 x 2.5
3×0.5
3×0.5
12
Skyline 125
Skyline 155
18
21
30
30
18
21
3 x 4
3 x 4
3×0.5
3×0.5