4) When the machine is running, there will be condensation water discharged from the bottom, please pay
attention to it. Please hold the drainage nozzle (accessory) into the hole and clip it well, and then connect a
pipe to drain the condensation water out.
b. The inlet and outlet water unions can't stand the weight of soft pipes. The heat pump must be connected with
hard pipes!
2. Wiring
a.
Connect to appropriate power supply, the voltage should comply with the rated voltage of the products.
b.
Earth the machine well.
c.
Wiring must be handled by a professional technician according to the circuit diagram.
d.
Set leakage protector according to the local code for wiring (leakage operating current ≤ 30mA).
e.
The layout of power cable and signal cable should be orderly and not affecting each other.
3. Electric wiring Diagram
-
For power supply: 230V 50Hz
Distribution Box (Customer prepare)
Power Supply
230V 50Hz
Earthing
Power Cord
Fuse
Breaker
Swimming Pool Heat Pump Wiring Board
11