Electric Gas Ignition; The Burner Flames - Fulgor Milano SOFIA PRO-RANGE F6PGR366S2 Instrucciones Para La Instalación

30-36
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

6 - Conversion for LP or NG Gas
EN
Proper adjustment will produce a stable, steady blue flame of
minimum size.
The final adjustment should be checked by turning the knob
from high to low several times without extinguishing the flame.
This adjustment, at low setting, will automatically provide the
proper flame size at medium setting.
After Conversion steps have been completed, check the
appearance of each burner's flame at the HI and LO settings,
if the flames appear too large or too small
review each step to make sure it was completed correctly.
NOTE: To obtain the correct minimum setting with LP gas, turn
clockwise tightening the valve(s) fully with the thin-blade
screwdriver into the recess behind control knob (A and /
or B).

Electric Gas Ignition

The gas burners use an electric ignition device located near
each burner ensures burners ignite automatically.
ELECTRIC IGNITION
See Use & Care manual for better explanation and its control.
22

The Burner Flames

Turn each burner on. Flames should be blue in color with no
trace of yellow. The burner flames should not flutter or blow
away from the burner The inner cone of the flame should be
between 1/2" and 3/4" long.
BURNER FLAMES
1/2" to 3/4"