Hansgrohe AXOR Uno2 38830 Instrucciones De Montaje página 6

Ocultar thumbs Ver también para AXOR Uno2 38830:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8
Attention! The fitting must be installed, flushed and
tested after the valid norms.
Assembly
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer in
position on the sink.
3. Slip the plastic washer, the slide washer, the metall
washer and collar over the hoses and threaded
base and tighten the collar nut by hand. If there
is not enough space, please use only the slide
washer and the metal washer without the plastic
washer.
4. Tighten screws.
5. Connect the connecting hose to the angle valves;
cold right - hot left.
The hot and cold supplies must be of equal
pressures.
Technical Data
Rate of flow at 0,3 MPa:
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Test certificate:
Operation
open

English
12 l/min
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80° C
65° C
WRAS
close
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled
continuous flow heaters if the flow pressure is at
least 0,15 MPa.
To adjust the hot water limiter on single lever mixers,
please see page 13.
No adjustment is necessary when using a continuous
flow water heater.
Spare parts (see page 3)
1
handle
1.1 screw cover
1.2 hollow set screw M6x10 DIN916 96029000
2
flange
3
nut
4
cartridge cpl.
5
seal
6
aerator cpl.
7
fixing set
8
connection hose 900 mm
9
spout cpl.
10
fixation extension
XXX = Colors
000 chrome plated
800 stainless steel optic
hot
38094XXX
96762000
96763XXX
97209000
92730000
95008000
97884XXX
13961000
96316000
97886XXX
13898000
cold
loading