Velleman VMB2BL Manual Del Usuario página 3

Ocultar thumbs Ver también para VMB2BL:
Idiomas disponibles
  • ES

Idiomas disponibles

Relay contacts for blind motor 1 control
1
2
Relay contacts for blind motor 2 control
3
12V supply
Velbus
4
Direct push button control blind 1 DOWN
5
6
Direct push button control blind 1 UP
7
Direct push button control blind 2 DOWN
Direct push button control blind 2 UP
8
9
Address setting
Enter a unique address (from '00' to 'FE' except for 'B1',
'C1', 'D1', 'E1', 'F1' and 'FF') for each module
10
Power LED
11
Reception LED
12
Fowarding LED
Termination
13
If the module is connected as the final device on the VELBUS,
place the 'TERM' jumper. Remove the jumper in all other
cases.
See also connection examples on page 22 & 23!
14
DOWN operation mode LED blind 1
15
UP operation mode LED blind 1
DOWN operation mode LED blind 2
16
17
UP operation mode LED blind 2
18
Indication LED DOWN blind 1
19
Indication LED UP blind 1
Indication LED DOWN blind 2
20
21
Indication LED UP blind 2
22
Manual UP control blind 2
Manual DOWN control blind 2
23
24
Manual UP control blind 1
25
Manual DOWN control blind 1
26
Switch-off delay setting
ENGLISH
3