USE
2.1
Installation conditions
All the infrared sensors must be in contact with the glass surface.
No movement of the control under the glass ceramic after installation must be
assured.
2.2
Printing on glass
The glass printing area over the sensors must be centred with the sensor.
Glass printing thickness in an area of 10mm around the centre of the keys <=
0.5mm.
2.3.
Type of glass
The glass thickness must be 4mm.
The glass infrared light transmission wavelength range must be around 925nm.
2.4.
User interface initial calibration
The User Interface has implemented an initial keyboard calibration focused to
adapt the sensibility of the keys, to the final mechanical, environmental and user
conditions.
Any time the Cooktop is plugged or there is a power failure that generates a
reset in the user interface, the first time the Key Lock is touched the sensitivity
of the keyboard is readjusted. This first touch of the Key Lock must be done in
certain conditions:
Do not use gloves
INSTRUCTIONS FOR USE
Use a clean finger
Touch the glass
(smooth touching)