Maintenance
Upper Grill & Fan
Upper Grill & Fan:
The upper fan may build
up residue and stick after extended use. This is
normal. Spray lightly with water or gently rotate fan
to free up mechanism.
DO NOT USE WATER ON LOWER GRILL & FAN!
Lower Grill & Fan:
White dust may appear on the
Lower Grill & Fan
lower grill. This is normal. Brush or blow dust off
DO NOT USE
WATER. Water will damage
internal electrical components behind the lower grill & fan
and void warranty!
Troubleshooting
RED LIGHT DOES NOT TURN ON:
check the vehicle's 12V DC receptacle fuse.
Check the fuse in the MiST™ connector (See MiST™ FUSE BLOWN below). If both
are OK, clean out the connectors and try again. The unit will not work with voltage
under 11.5V DC. Ensure the vehicle is running and the A/C is "ON". Verify the voltage
with a volt meter. If the 12V DC connection supplies erratic or too little voltage, an
optional extension cord (sold separately) is available to connect to the vehicle's
battery. If voltage is correct, proceed by pushing down the red start button. The solid
green light should come on and the unit should begin to mist. This confirms that the
unit is functioning properly and the red light is defective. If there is no green light and
the unit still will not function CALL CUSTOMER SERVICE.
MiST™ FUSE BLOWN:
Replace the standard fuse (10 amp) inside the 12V DC
adapter of the MiST™ unit by unscrewing the end. Ensure vehicle is running and A/C
is "ON" to provide proper power levels to the MiST™ unit.
GREEN LIGHT IS BLINKING QUICKLY:
This is a trouble code signaling that the
MiST unit is receiving a lower voltage than the 11.5V DC. Clean receptacle and
check the vehicle's charging system, it may be fluctuating lower than the 11.5V DC
required. If that is the case, connect directly to the vehicle's battery with the optional
extension cord (sold separately). Ensure that the vehicle is running and the A/C is
"ON" to provide proper power levels to the MiST™ unit. If this doesn't work CALL
CUSTOMER SERVICE.
RESTARTING THE UNIT:
Power must be disconnected to clear the unit's
code by disconnecting and reconnecting the 12V DC adapter. Be sure to check the
fluid level before restarting.
RED AND GREEN LIGHTS ARE ON (SOLID) AND THE MiST™ UNIT IS NOT
MISTING:
Shut the unit off and check the fluid levels to ensure it is above the
minimum level, then restart and allow the unit to operate for a few minutes and check
that the upper fan is operating. (See maintenance at the top of this page.) If the unit
still produces no mist CALL CUSTOMER SERVICE. If the unit was running empty
(without fluid) then the piezos have burned out. This is NOT covered under warranty!
– 11 –