Converting to a different gas type
Changing the injector orifices
The cooktop is set to NG. A conversion kit to
LPG is supplied with the cooktop.
To change the injector orifices, you will need
9
a
/
" (7 mm) box spanner.
32
1
Turn off the cooktop and disconnect from
the main electrical supply.
WARNING!
Electrical Shock Hazard inside.
2
Make sure all gas valves are turned off.
3
Remove all grates and burner parts.
4
Unscrew the orifices (save for future use)
and replace them with the correct ones
(size numbers are stamped on the side, eg
70= 0.70 mm) (see fig. 1).
5
Remove the 2 screws holding each burner
bowl (3 on the wok burner).
6
Lift hob tray from the product.
WARNING!
Cut Hazard - sharp edges.
7
Replace the wok orifice with the correct
13
one using a
8
Reset the venturi (see fig. 2):
With the product isolated from the electrical
supply, ignite the burner using a match.
The flame will probably be lifting off the
burner (see fig. 3).
Loosen the venturi securing screw. Move
the venturi towards the injector until the
flame begins to 'yellow tip' (see fig. 4).
Move the venturi back until the 'yellow
tip' just disappears (see fig. 5) - this is the
correct venturi setting. Tighten the securing
screw.
9
To re-fit the hob tray, repeat steps 5&6 in
reverse.
10
IMPORTANT! Reset the minimum setting
(see 'Minimum setting or turn down').
11
After re-assembly verify the insulation
resistance and earth continuity of the
electrical circuit.
8
/
" (10 mm) ring spanner.
32
Continued...
12
The label supplied with the orifices should
be placed over the existing gas type label
to indicate the change.
lifting off
figure 3
good flame
figure 1
venturi
figure 2
yellow tip
figure 4
figure 5