DIVERSITECH Asurity PROCP-16 Instrucciones De Instalación página 10

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ASU RI TY
T M
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE CORRECTIVE ACTION
Unit does not
1. Power is not
start when full of
supplied to pump.
condensate
2. Pump impeller is
not turning.
Condensate is
1. Power is not
overflowing
supplied to pump.
from unit
2. Pump is not level.
3. Outlet flow is
blocked.
4. Pump impeller is not
turning.
Pump will not
1. Outlet flow is
shut off
blocked.
WARRANTY
All pumps manufactured by or for DiversiTech Corporation (the Company)
and sold by the Company under the the Asurity or DiversiTech brand are
warranted to be free of defects in workmanship and materials for a period
of 36 months from date of sale from the distributor to the contractor. The
Company will credit, repair or replace, at its option, any Pump if deemed
defective within this time period. All products returned to the Company
must include a return authorization issued by the Company. The returned
product should be suitably packaged and shipped prepaid from the point of
shipment to the point designated in the Company's return authorization.
This warranty is a limited warranty and shall be in lieu of any other
warranties, expressed or implied, including, but not limited to, any implied
warranty of merchantability or fitness for a particular purpose. There are
no other warranties that extend beyond the description of the face hereof.
The liability of the Company arising out of its supply of said products, or
their use shall not in any case exceed the cost of correcting defects in the
products as set forth above. The Company shall not be liable for any costs
or damage incurred by its customers in the removal or replacement of
defective products from units in which the products have been assembled.
In no event shall the company be liable for loss of profits, indirect,
consequential, or incidental damages.
C O N D E N S AT E M A N A G E M E N T
1. Take top of pump off of tank and move the float up
by hand. The pump motor should turn on, the fan
should be visibly spinning through the top of the
deck cover, and the fan should be audible.
2. Clear any blockage in impeller housing. If problem
persists, motor is stuck. Return pump to place of
purchase if under warranty.
1. Take top of pump off of tank and move the float up
by hand. The pump motor should turn on, the fan
should be visibly spinning through the top of the
deck cover, and the fan should be audible.
2. Check to ensure that pump is level. If pump is not
level, it may not activate, causing water to overflow
from tank. Place unit on a flat and level surface.
3. Check outlet tubing to ensure that it is not kinked or
blocked. Clear blocked tubing of slime and debris.
Clean inlet and outlet piping.
4. Clear any blockage in impeller housing. If problem
persists, motor is stuck. Return pump to place of
purchase if under warranty.
1. Check outlet tubing to ensure that it is not kinked or
blocked. Clear blocked tubing of slime and debris.
Clean inlet and outlet piping.