Bosch Professional GEX 125 AVE Manual Original página 17

Ocultar thumbs Ver también para Professional GEX 125 AVE:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
OBJ_BUCH-1330-003.book Page 16 Wednesday, October 26, 2011 11:52 AM
16 | English
Replacing the Sanding Sheet (see figure A)
To remove the sanding sheet 10, lift it from the side and pull it
off of the sanding plate 8.
When attaching a new sanding sheet, remove any dust or de-
bris from the sanding plate 8, e. g., with a brush.
The surface of the sanding plate 8 is fitted with Velcro backing
for quick and easy fastening of sanding sheets with Velcro ad-
hesion.
Press the sanding sheet 10 firmly against the bottom side of
the sanding plate 8.
To ensure optimum dust extraction, pay attention that the
punched holes in the sanding sheet match with the holes in
the sanding plate.
Selection of the Sanding Plate
Depending on the application, the machine can be equipped
with sanding plates of different hardness:
– Sanding plate, extra soft: Suitable for polishing and sensi-
tive sanding, incl. on convex surfaces.
– Soft sanding plate: Suitable for all sanding applications
and general-purpose use.
– Hard sanding plate: Suitable for high sanding capacity on
flat surfaces.
Replacing the Sanding Plate (see figure B)
Note: Replace a damaged sanding plate 8 immediately.
Pull off the sanding sheet or polishing tool. Completely un-
screw the screw 11 and take off the sanding plate 8. Attach
the new sanding plate 8 and tighten the screw again.
Note: When attaching the sanding plate, pay attention that
the toothing of the drive element engage into the openings of
the sanding plate.
Note: A damaged sanding-plate base may be changed only by
an authorised after-sales service agent for Bosch power tools.
Dust/Chip Extraction
Dusts from materials such as lead-containing coatings,
some wood types, minerals and metal can be harmful to
one's health. Touching or breathing-in the dusts can cause
allergic reactions and/or lead to respiratory infections of
the user or bystanders.
Certain dusts, such as oak or beech dust, are considered
as carcinogenic, especially in connection with wood-treat-
ment additives (chromate, wood preservative). Materials
containing asbestos may only be worked by specialists.
– As far as possible, use a dust extraction system suitable
for the material.
– Provide for good ventilation of the working place.
– It is recommended to wear a P2 filter-class respirator.
Observe the relevant regulations in your country for the
materials to be worked.
Prevent dust accumulation at the workplace. Dusts can
easily ignite.
2 609 932 821 | (26.10.11)
Integrated Dust Extraction with Dust Box (see figures C–G)
Mount the dust box 7 onto the extraction outlet 12. Turn the
dust box in such a manner that its recesses face against the
tips on the extraction outlet and the dust box can be felt to en-
gage.
The filling level of the dust box 7 can easily be checked
through the transparent container.
To empty the dust box 7, pull it off toward the rear with a slight
twisting motion.
Screw the filter element 6 on and pull it out of the dust box 7.
Empty the dust box.
To loosen the dust, gently strike or tap the filter element 6
against a firm surface. Clean the lamellas of the filter element
6 with a soft brush.
Note: To ensure optimum dust extraction, empty the dust box
7 in good time and clean the filter element 6 at regular inter-
vals.
When working vertical surfaces, hold the power tool in such a
manner that the dust box 7 faces downward.
External Dust Extraction (see figure H)
Mount a vacuum hose 13 onto the extraction outlet 12. Mount
the vacuum hose onto the extraction outlet (as shown in the
figure) in such a manner that the lateral openings on the ex-
traction outlet remain free. This prevents the power tool from
adhering to the workpiece during sanding and the surface
quality of the workpiece from being impaired.
Connect the vacuum hose 13 to a vacuum cleaner (accesso-
ry). An overview for connecting to various vacuum cleaners
can be found at the end of this manual.
The vacuum cleaner must be suitable for the material being
worked.
When vacuuming dry dust that is especially detrimental to
health or carcinogenic, use a special vacuum cleaner.
When working vertical surfaces, hold the power tool in such a
manner that the vacuum hose faces downward.
Auxiliary Handle
The auxiliary handle 1 enables convenient handling and opti-
mal distribution of power, especially at high removal rates.
Fasten the auxiliary handle 1 with screw 2 to the casing.
Operation
Starting Operation
Observe the mains voltage! The voltage of the power
source must correspond with the data on the type plate of
the machine.
Switching On and Off
To start the machine, press the On/Off switch 4.
To lock the On/Off switch, keep it pressed and additionally
push the lock-on button 5.
To switch off the machine, release the On/Off switch 4. When
the On/Off switch 4 is locked, press it first and then release it.
Bosch Power Tools
Tabla de contenido
loading

Este manual también es adecuado para:

Professional gex 150 aveProfessional gex 125-150 ave

Tabla de contenido