English
5. WARRANTY
Except as otherwise stated, our warranty is valid for 2 years starting from the date on which
the equipment was sold. Extract from our General Conditions of Sale provided on request.
The warranty does not apply in the following cases:
Inappropriate use of the equipment or use with incompatible equipment
Modifications made to the equipment without the explicit permission of the
manufacturer's technical staff
Work done on the device by a person not approved by the manufacturer
Adaptation to a particular application not anticipated in the definition of the
equipment or not indicated in the user's manual
Damage caused by shocks, falls, or floods.
6. TO ORDER
Delivered with
a paper user's manual, 5 languages
a set of 2 x 1.5V batteries AA
Test lead elbowed 1,5 m red with 4 mm probe tips
Test lead elbowed 1,5 m black with 4 mm probe tips
K adaptator + sensor
Optional (references : consult http://www.chauvin-arnoux.com)
Probes
Set of Test lead RD/BK with test probes-elbowed male banana plugs PVC
Set of Test lead RD/BK with test probes-elbowed male banana plugs silicon
Test probes cat III/IV
Crocodiles clips
Safety adapter and K sensor Temperature probe for multimeter
banana inputs with 18 mm spacing measurement from -50°C to +350°C
K sensor adapter and Temperature probe for multimeter
banana inputs with 18 mm spacing measurement from -50°C to +200°C
Miscellaneous
Carrying case
External charger for accu. 1.5V
Fuse
Fuse F 1000V 10A 10x38mm
Fuse F 1000V 0.63A 6.3x32mm
7. GENERAL SPECIFICATIONS
Mechanical features
Dimensions
170 x 80 x 50 mm
Weight
320 g (with batteries)
Packing blister
266 x 132 x 70 mm
Power supply
Batteries
2 x 1.5V AA
Battery life
approx. 500 hours in VLowZ / VAC without backlight
Climatic conditions
Reference temp.
23°C ± 3°C
Use temperature
-20°C to 55°C
Storage temp.
-40°C to 60°C
Relative humidity
< 90 % RH (up to 45°C) without condensation
Protection rating
IP 54
Safety
IEC 61010-1 / EN 61010-02-030 / EN 61010-2-033
Insulation
class 2 double isolation
Pollution degree
2
Use
indoor
Altitude
< 2000 m
Category
CAT III, 600 V max. to earth
EMC
complies EN 61326-1
8. TECHNICAL SPECIFICATIONS (See Appendix, p. 57)
Referal conditions
Temperature
+23°C ± 3°C.
Humidity
45% to 75% RH
Supply
Full battery (no low bat signal display) or accu. 1.5 VAA Ni-MH
Freq. for AC signal
45-65 Hz
Pure AC signal
No other rotating magnetic field
No other electrical field
General measure characteristics
• in DC
AC ≤0,1% of the DC signal
• in AC
DC < 0,1% of the AC signal
23
4000- and 6000-count TRMS digital multimeters