Troubleshooting

NOTICE
BEFORE DISCONNECTING ANY TUBES, MAKE SURE TO TURN OFF
WATER SUPPLY AND MAKE SURE THE SYSTEM IS DEPRESSURIZED
PROBLEM
1. Low/Slow production
2. Milky colored water
3. Water constantly running, unit will not shut off
4. Noise / Water from faucet vent hole or noise from in drain
line drain.
5. Small amount of water in storage tank
6. Low water flow from faucet
For additional troubleshooting procedures visit PremierH2O.com or contact our Technical
Support team at 800-752-5582.
CAUSE
Low water pressure
Crimps in tubing
Clogged pre-filters
Fouled membrane
Air in system
Low water pressure
Crimp in supply tube
High water pressure
High pressure in Tank
Low Pressure in Tank
Crimp or restriction
Drain tube clogged
System starting up
Low water pressure
To much air in tank
10
SOLUTION
Assure a minimum of 40psi incoming water pressure.
Watts sells a booster pump if home water pressure is low.
Make sure water supply is turned on and Adapt-A-Valve™ is
all the way open.
Check tubing and straighten or replace as necessary.
Replace pre-filters.
Replace membrane and flow restrictor.
Air in the system is a normal occurrence with initial start up
of the RO system. This milky look will disappear during normal
use within 1-2 weeks. If condition reoccurs after filter change,
drain tank 1 to 2 times.
See #1 above
Check tubing and straighten or repair as necessary.
Check incoming water pressure to make sure it does not
exceed 80psi. A pressure relief valve may be necessary.
Empty storage tank of water. Set tank air pressure between
5-7psi. See previous page.
Use a Digital Air Gauge for best results. The empty tank
pressure should be 5-7psi. See Page 9.
Check tubing and straighten or repair as necessary.
Straighten all drain lines. Clear blockage. Cut off any
excess tubing
Caused from dishwasher or garbage disposal.
Disconnect the
" black line at the drain, clean the
3
8
line out with a wire, then reconnect. Blowing air through the
line will not always remove the clog.
Normally it takes 4-6 hours to fill tank. Note: low incoming
water pressure and/or temperature can drastically reduce
production rate.
See #1 above.
Tank air pressure should be 5-7psi when empty of water.
If below 5psi, add air or bleed if above 7psi.
Check only when tank is empty of water. See previous page.
Check air pressure in tank
Use a Digital Air Gauge for best results. The empty tank
pressure should be 5-7psi. See Page 9.
" black