Tabla De Contenido; Safety Information - HAMPTON BAY 51548 Guía De Uso Y Mantenimiento

Ventilador de techo tucson de 1.22 m
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Table of Contents
Table of Contents ................................................................ 2
Safety Information ............................................................... 2
Warranty ............................................................................... 3
Pre-Installation .................................................................... 3
Installation ............................................................................ 6

Safety Information

1.
All wiring must be in accordance with the National Electrical
Code ANSI/NFPA 70 and local electrical codes. Electrical
installation should be performed by a qualified licensed
electrician.
2.
The outlet box and support structure must be securely mounted
and capable of reliably supporting 35 lbs. (15.9 kg). Use only
UL Listed outlet boxes marked "Acceptable for Fan Support of
35 lbs. (15.9 kg) or less."
3.
The fan must be mounted with a minimum of 7 ft (2.1 m)
clearance from the trailing edge of the blades to the floor.
4.
Do not operate the reversing switch while the fan blades are in
motion. You must turn the fan off and stop the blades before
you reverse the blade direction.
5.
Do not place objects in the path of the blades.
Electrical diagrams are for reference only. Light kits that are not
6.
packed with the fan must be UL listed and marked suitable for
use with the model fan you are installing. Switches must be UL
General Use Switches. Refer to the instructions packaged with
the light kits and switches for proper assembly. Use 14W CFL
bulbs max (included).
7.
After making electrical connections, spliced conductors should
be turned upward and pushed carefully up into the outlet box.
The wires should be spread apart with the grounded conductor
and the equipment-grounding conductor on one side of the
outlet box.
All setscrews must be checked and retightened where
8.
necessary before installation.
9.
Suitable for use in wet locations when installed in a GFCI
protected branch circuit. Use only with light kits marked
"Suitable for use in wet locations".
Assembly .............................................................................. 7
Operation ........................................................................... 13
Care and Cleaning ............................................................. 14
Troubleshooting ................................................................. 14
WARNING: To reduce the risk of personal injury,
do not bend the blade brackets (also referred to as
flanges) during assembly or after installation. Do not
insert objects in the path of the blades.
WARNING: Remove the rubber motor stops on
the bottom of the fan before installing the blades or
testing the motor.
WARNING: To reduce the risk of fire or electric
shock, do not use this fan with any solid-state speed
control device.
WARNING: To reduce the risk of fire, electric shock
or personal injury, mount to outlet box marked
"acceptable for fan support of 35 lbs. (15.9 kg) or
less" and use screws provided with the outlet box.
WARNING: To avoid possible electrical shock,
turn the electricity off at the main fuse box before
wiring. If you feel you do not have enough electrical
wiring knowledge or experience, contact a licensed
electrician.
CAUTION: To reduce the risk of personal injury,
use only the screws provided with the outlet box.
CAUTION: To avoid personal injury or damage to the fan
and other items, use caution when working around or
cleaning the fan.
2

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

685 196Ef200s-48Ef200sp-48

Tabla de contenido