Preparation For Operation - VERTO 52G449 Manual De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
GWARANCJA I SERWIS
Warunki gwarancji oraz opis postępowania w przypadku reklamacji
zawarte są w załączonej Karcie Gwarancyjnej.
Serwis Centralny
GTX Service
Ul. Pograniczna 2/4
02-285 Warszawa
Sieć
Punktów
Serwisowych
i pogwarancyjnych dostępna na platformie internetowej gtxservice.pl
Grupa Topex zapewnia dostępność części zamiennych oraz
materiałów eksploatacyjnych dla urządzeń i elektronarzędzi.
Pełna oferta części i usług na gtxservice.pl. Zeskanuj kod QR i wejdź:
GB
TRANSLATION OF THE ORIGINAL INSTRUCTIONS
SUBMERSIBLE PUMP FOR DIRTY WATER
52G449
CAUTION: BEFORE USING THE TOOL READ THIS MANUAL CAREFULLY
AND KEEP IT FOR FUTURE REFERENCE.
DETAILED SAFETY REGULATIONS
SAFETY OF USER OF SUBMERSIBLE PUMP FOR DIRTY WATER
• Connection to mains network should be done by a licensed
electrician and accordingly to IEC 364. Use of residual current device
is required, which breaks the circuit when earth leakage current
exceeds 30mA for 30 ms.
• Do not direct the pump water stream onto people, electric
equipment and the device itself.
• Disconnect the pump from power supply when performing
maintenance tasks.
• Children are not allowed to operate the pump.
• Do not pull or hold the pump by its power cable or water hose. Use
corrosion resistant cord attached directly to the pump handle for this
purpose.
• To ensure safe operation use only spare parts that are approved by
the manufacturer or original.
• Use connectors and equipment supplied by the manufacturer.
• Do not use the pump in case of damage of power cable or any other
part of the device, e.g. residual current device, water hose etc.
• When extension cord is used, socket and plug should use earthing
prong (connection).
• The pump is designed for household use.
• The pump can be used indoors and outdoors.
• Water float must rest freely on water surface, it should not have
contact with obstacles. Blocked movement may cause pump
damage.
tel. +48 22 573 03 85
fax. +48 22 573 03 83
do
napraw
gwarancyjnych
• The pump is designed so all moving parts and the casing allow
for safe operation. The manufacturer is not responsible for
losses resulting from modifications of the device.
• Do not use the pump for liquids other than water, especially engine
fuels, cleaning liquids and other chemical products.
CAUTION! The design is assumed to be safe, protection measures
and additional safety systems are used, nevertheless there is
always a small risk of operational injuries.
CONSTRUCTION AND USE
Submersible water pump is a I protection class device designed for
pumping out clean water or dirty water containing particles with
maximum diameter of 35 mm. The pump is designed to operate under
water. When installed in appropriate well, it may be protection against
flooding. It is ideal for removing water from garages, basements, tanks
or excavations flooded with rain water. The pump is designed to pump
water at maximum temperature 35
Special base is specific feature of the pump, it allows to pump out the
water down to 5 cm level. The pump features automated float switch,
which allows the pump to switch on and off by itself. It protects against
dry operation. Built-in vent valve allows easy water suction.
Use the pump according to the manufacturer's instructions only.
DESCRIPTION OF DRAWING PAGES
Below enumeration refers to the device elements depicted on the
drawing pages of this manual.
1. Handle
2. Float switch
3. Inlet holes
4. Connection
5. Connector pipe
* Differences may appear between the product and drawing.
MEANING OF SYMBOLS
CAUTION
WARNING
ASSEMBLY/SETTINGS
INFORMATION
EQUIPMENT AND ACCESSORIES
1. Connector pipe
2. Connection

PREPARATION FOR OPERATION

PUMP ASSEMBLY
There is outlet hole in the submersible pump base, that is used to attach
connection and connector pipe, and then appropriate water hose.
• Attach connection (4) by screwing it into hole in the pump base.
• Screw connector pipe (5) onto attached connection (4).
• Join water hose and connector pipe (5).
PUMP INSTALLATION
Do not use the pump in a position, when it is not supported, but
hung on water hose or power supply cable.
Submersible pump should be hung on properly constructed support,
hung on a cord or placed at the bottom of a well. Keep bottom of the well
clean and free from sludge to ensure proper operation of the pump.