Dmx Junction Box Wiring - Iluminarc Ilumipanel 40 IP Optic WW Guía De Referencia Rápida

Ocultar thumbs Ver también para Ilumipanel 40 IP Optic WW:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

EN
AC Power
Junction Box
Wiring
DMX Linking
DMX Connection
Signal Wiring
DMX Junction
Box Wiring
Signal In
All manuals and user guides at all-guides.com
From
Fuse
Panel
Distribution
Box
The Ilumipanel 40 IP Optic WW will work with a DMX controller using a
regular DMX serial connection. A DMX Primer is available from
www.iluminarc.com.
This product provides a DMX 512 connection by using bare-ended
IP67-rated signal cable. This cable comes connected to the product. See the
User Manual to connect and configure for DMX operation.
To provide the signal, you have two options:
Connect the bare-ended IP67-rated signal cable from the product to two
IP67-rated signal connectors (DMX In and DMX Out).
Use an IP67-rated junction box. If so, make sure to use IP67-rated
conduit.
The signal cable must match or exceed the electrical characteristics of
the Belden® 9841 cable for EIA RS-485 applications. You can also use
CAT 5, CAT 5e, or CAT 6.
Junction Box
Ilumipanel 40 IP Optic WW QRG
L :
Black
N :
White
G :
Green
Distribution
Conduit
1: Common (Shield)
2: Data – In (Black)
3: Data + In (White)
4: Data – Out (Green)
5: Data + Out (Red)
Conduit
3
To
Other
Boxes
Box
Signal Out
Junction Box
Tabla de contenido
loading

Tabla de contenido