Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 34)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Dimensions (see page 36)
Flow diagram (see page 36)
Fault
Mixer stiff
Mixer dripping
Water escaping in area of swivel
spout
Water escaping at the threaded
base
Hot water temperature too low
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- O-ring defective
- O-ring at the connection hose
defective.
- Hot water limiter incorrectly set
Assembly (see page 33)
English
Spare parts (see page 38)
XXX = Colors
000 = Chrome Plated
800 = Stainless Steel Optic
Cleaning (see page 37)
Operation (see page 35)
Test certificate (see page 40)
Remedy
- Exchange cartridge
- Exchange cartridge
- Exchange O-ring
- Exchange O-ring
- Set hot water limiter