Start-Up And Operation - Astralpool COMPACT ELECTRICHEAT 60170 Manual Técnico, Arranque Y Funcionamiento

Ocultar thumbs Ver también para COMPACT ELECTRICHEAT 60170:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 8
3.8 CHANGING DEFAULT FLOW DIRECTION
Factory default flow direction is from right to left. If changing default flow direction is needed
follow the steps described on images 11.
WARNING
Remember: if flowswitch is reversed, so has to be the connector of temperature
probes. See images 13.
4

START-UP AND OPERATION

Unit
ON or OFF
Inlet
Temperat.
The unit will show if it is heating water by means of this icon on the lower right side of the screen:
The unit is idle:
no water heating.
Heating water at 2/3 of total power of the unit happens to achieve a soft start and when the water
temperature is close to the set point to achieve a soft set point reach.
1) Once installation of the heater is complete, connect
electrical supply to the unit. The screen will display that
the unit is off and that there is no water flow.
2) Press "+" or "-" buttons to set the desired set point
temperature. If necessary press "ºC/ºF" button to set your
prefered temperature scale.
3) Then start the filtration pump to start water flow and purge
the system of air. The screen will show that now there is
water flow.
4) Then press Start / Stop button, to activate the heater.
5) At this point the heater will start heating water if water
temperature is below set point. On the other hand, if water
temperature is equal or greater than set point the unit will
remain idle.
Set Point
W=0 No Flow
ºC or ºF
Temp.
W=1
Outlet
Temperat.
The unit is heating water
at 2/3 of total power.
Changes temperature
Flow
Increases
Power
level
temperature setpoint.
Starts or stops the
scale: ºC or ºF
Decreases temperature
The unit is heating
water at full power.
heater
setpoint.
Pg. 4
Tabla de contenido

Solución de problemas

loading

Tabla de contenido