Output indicator is flashing
The wire does not come out correctly
The wire does not come out at the proper
speed
Shielding gas doesn't comes out
The arc is not stable and the wire collides with
the workpiece.
The arc doesn't starts
Incorrect arc startup
Low penetration
Pores in the weld
Projections
Unstable arc
ALARMS AND ANOMALIES
Nº ERROR
CAUSE
Er 1
Corrupt data memory
Er 2
Internal error in the memory
Er 3
Error in data memory
Er 4
Communication error with the
regains a safe temperature.
The equipment has found that the torch push button was pressed
during startup or when recovering from an overtemperature fault.
Release the button of the torch and/or pedal.
Verify that the drive system rotates correctly.
Verify that the coil brake is not too tight.
Verify that the drive system accessories are in good conditions.
Verify that the torch and consumables are in good conditions.
At the beginning of the welding, the wire always comes out with a
minimum speed. Verify that the wire feeding system works properly
with the manual feeding button.
Check that there is gas in the bottle.
Check that the flow rate adjustment is correct.
Verify that torch is not pinched and / or perforated.
Gas valve defective.
Check if the material used corresponds to the selected in the
machine.
Verify that consumables and rollers are appropriate with the material
in use.
The output terminals aren't in contact with the workpiece.
Incorrect polarity
Welding cables in bad condition.
Bad electrical connections.
Dirty and/or rusty piece.
Incorrect settings.
Low welding current.
Excessive welding speed.
Reversed polarity.
Shortly gas flow or improper gas.
Faulty torch consumables.
Excessive welding current.
Incorrect dynamics settings.
Incorrect welding position.
Wrong welding program.
Piece with oxide or badly prepared for welding.
Check the contact clamp and torch consumables
Inadequate welding program
SOLUTION
This error is solved automatically. The default data will be loaded.
Send the equipment to the technical service for an overhaul.
This error is solved automatically and the equipment can carry on
working.
The machine loads a set of default parameters and can carry on
working.
Turn off the equipment for a minute and re-start it. If the error
41