Genie Directlift 2060 Manual De Operación Y Mantenimiento página 14

Ocultar thumbs Ver también para Directlift 2060:
2060-3060 eng.qxd
11/9/05
TROUBLESHOOTING
Safe-T-Beam® System Self-Diagnostic Troubleshooting
Source (Red LED)
ON
OFF
OFF
2 BLINKS, Pause
(Repeat)
2 BLINKS, Pause
(Repeat)
3 BLINKS, Pause
(Repeat)
4 BLINKS, Pause
(Repeat)
14
11:02 AM
Page 14
Sensor (Green LED)
ON
OFF
ON
ON
OFF
ON
ON
Possible Problem
Normal operation
• Power Head not powered
• Wiring from Power Head bad
• Wiring to Source missing or bad • Check wiring
• Power has been interrupted
• Beam not aligned
• Beam obstructed
• Sensor defective
• Wire to Sensor missing or bad
• Sensor defective
• Sensor receiving interference
• Source not sending pulses
• Source defective
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
Solution
None required
• Check breakers, fuses, plugs
• Check wiring for obvious shorts
• Remove power and reapply
• Check Source, Sensor alignment
• Check for obstruction
• Contact Customer Service
• Check wiring
• Contact Customer Service
• Determine source of interference
• Check for interference from sun-
light or a source unit on an
adjacent door
• Contact Customer Service
• Contact Customer Service
• Contact Customer Service

Capítulos