Fein BF10-280E Instrucciones De Uso página 7

Ocultar thumbs Ver también para BF10-280E:
Idiomas disponibles

Idiomas disponibles

OBJ_DOKU-0000000387-001.fm Page 7 Thursday, July 1, 2010 2:52 PM
Extension cable.
If the use of an extension cable
WARNING
is required, its length and con-
ductor cross-section must be adequate for the
applicational case, in order to prevent a volt-
age drop in the extension cable, power loss
and overheating of the power tool. Other-
wise, the extension cable and power tool are
liable to electrical danger, and the working
efficiency is impaired.
Intended use of the power tool:
Hand-guided belt file for dry sanding and pol-
ishing of metal materials with belts, in
weather-protected environments using the
application tools and accessories recom-
mended by FEIN.
Operation of the power tool off power
generators.
This power tool is also suitable for use
with AC generators with sufficient power
output that correspond to the Standard ISO
8528, design type G2. This Standard is partic-
ularly not complied with when the so-called
distortion factor exceeds 10 %. When in
doubt, please refer to the generator instruc-
tion/specification guide.
Operating the power tool off
WARNING
power generators whose no-
load speed exceeds the voltage value on the
type plate of the power tool is prohibited.
Recommended dimensions of extension
cables at an operating voltage of 120 V – sin-
gle-phase a. c., with only one power tool
BF10-280E connected:
Min. conductor size
Min. conductor
(A.W.G.)
cross-section, mm
≤ 100
100
200
–200
–300
Max. cable length, ft
Max. cable length, m
16
14
12
en
7
2
≤ 30
30
60
– 60
–100
1.5
2.5
4
loading

Este manual también es adecuado para:

7 228 05