Beam Angle
Adjustment
Ilumipod Inground Tri-12 IP Optic WW QRG
The Ilumipod Inground Tri-12 IP Optic WW has 2 LED modules. You can
adjust the angle of each of these modules to spread or narrow the fixture's
beam.
·
Loosen the ¼-turn Allen bolts on the stainless steel collar.
·
Lift the fixture from the installation sleeve, making sure not to stretch
the power and signal cables.
·
Loosen the six nuts that hold the collar to the housing, except two
adjacent ones.
·
Wait a few seconds for the seal to expand. This lowers the possibility of
damaging the seal.
·
Complete the removal of the two remaining nuts.
·
Remove the stainless steel collar.
·
Carefully lift and remove the protective glass and seal. Make sure not to
reverse the glass.
·
Using only your hands, push on the sides of each module to adjust its
angle, as shown in the figure below.
·
Replace the glass and seal.
·
Replace the stainless steel collar, making sure to allow the Allen screws
to show and that the glass is flushed with the collar.
·
Replace all six nuts and adjust them manually until they touch the
housing.
·
Tighten the nuts uniformly by alternating between opposite nuts.
·
Reattach the fixture to the installation sleeve.