3. Proper use

The equipment you have purchased is designed
to pump water with a maximum temperature of
35 °C. This equipment must never be used for
other liquids, especially not for engine fuels,
cleaning agents and other chemically-based
products!
The equipment can be used wherever you want to
move water, e.g. in the house, in the garden, and
for many other applications. It must not be used to
operate swimming pools!
If you want to use the equipment in bodies of wa-
ter with a natural, muddy bottom, place the equip-
ment in a slightly elevated position, e.g. on bricks.
The equipment is not designed for continuous
operation, e.g. as a circulating pump in a pond. In
this case the equipment's anticipated life will be
greatly shortened because the equipment was
not designed for continuous loading.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
The water may be contaminated by escaping lub-
ricating oil/lubricant.
Anl_NCSP_E_60_i_SPK7.indb 14
Anl_NCSP_E_60_i_SPK7.indb 14
GB

4. Technical data

Mains connection ........................... 230 V ~ 50 Hz
Power rating ............................................... 600 W
Max. pumping rate .................................17000 l/h
Max. delivery head ...................................... 7,5 m
Max. submersion depth .................................. 5 m
Max. water temperature ............................... 35°C
Hose connection .......approx. 47,8 mm (G 1 ½) IG
Max. size of foreign bodies: ....................Ø 15 mm
Switching point height: ON .....max. approx. 50 cm
Switching point height: OFF ......min. approx. 5 cm
Protection type. .............................................IPX8

5. Before starting the equipment

Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
5.1 Installation
The equipment can be installed either:
Stationary with a rigid pipe line
or
Stationary with a flexible hose line
Notice!
Before you use the pump, clarify any possible
special conditions which need to be fulfi lled for
the installation!
For example, additional safety measures may be
needed if damage to property could result from a
power failure, soiling or a defective gasket.
Examples of such safety measures:
Pumps running in parallel on a separately protec-
ted power circuit, moisture sensors for switching
off the pumps, and similar safety arrangements.
Be sure to consult a professional plumber if you
have any doubt.
The maximum pumping rate is possible only with
the largest possible line diameter; if smaller hoses
or pipes are connected, the pumping rate will be
reduced. Flexible hose lines must be fastened to
the hose connection with a hose clip (not inclu-
ded in the scope of supply).
When installing, never hang the equipment by the
discharge line or by the power cable. The equip-
ment must be hung up with the provided carry
handle or it must rest on the bottom of the shaft.
To ensure that the equipment works properly, the
- 14 -