Model Ws-30 Installation; Important Note - Sub-Zero 424G Manual Del Usuario

Ocultar thumbs Ver también para 424G:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

MODEL WS-30 INSTALLATION

Anti-Tip Bracket
CONCRETE WEDGE ANCHOR INSTALLATION
Drill a
3
/
"
diameter hole any depth exceeding the
(10)
1
8
minimum embedment. Clean the hole or drill additional
depth to accommodate drill fines.
Assemble the washer and nut flush with the end of
2
anchor to protect threads. Drive the anchor through the
material to be fastened until the washer is flush with the
surface material.
Expand the anchor by tightening the nut 3–5 turns past
3
hand-tight position or to 25 ft-lb of torque.
WARNING
Verify there are no electrical wires or plumbing in the
area which the screws could penetrate.
CAUTION
Always wear safety glasses and use other necessary
protective devices or apparel when installing or working
with anchors.
Anchors are not recommended for use in lightweight
masonry material such as block or brick, or for use in
new concrete which has not had sufficient time to cure.
The use of core drills is not recommended to drill holes
for the anchors.
Custom Panels
For overlay and flush inset applications, custom door and
grille panels must be installed. Panel size is critical for a
proper fit. To verify panel requirements and dimensions,
refer to the Sub-Zero design guide at subzero.com/specs.
Flush inset applications require a

IMPORTANT NOTE:

minimum
1
/
"
reveal on all sides.
(13)
2
Finish all sides of the custom panel. They may be visible
when the door is open or through the glass door.
CAUTION
A solid panel cannot be installed over the glass door.
|
subzero.com
25
Tabla de contenido
loading

Este manual también es adecuado para:

424fsg427g427rgWs-30

Tabla de contenido