MODEL 427G / 427RG INSTALLATION

Anti-Tip Bracket
CONCRETE WEDGE ANCHOR INSTALLATION
Drill a
3
/
"
diameter hole any depth exceeding the
(10)
1
8
minimum embedment. Clean the hole or drill additional
depth to accommodate drill fines.
Assemble the washer and nut flush with the end of
2
anchor to protect threads. Drive the anchor through the
material to be fastened until the washer is flush with the
surface material.
Expand the anchor by tightening the nut 3–5 turns past
3
hand-tight position or to 25 ft-lb of torque.
WARNING
Verify there are no electrical wires or plumbing in the
area which the screws could penetrate.
CAUTION
Always wear safety glasses and use other necessary
protective devices or apparel when installing or working
with anchors.
Anchors are not recommended for use in lightweight
masonry material such as block or brick, or for use in
new concrete which has not had sufficient time to cure.
The use of core drills is not recommended to drill holes
for the anchors.
|
14
Sub-Zero Customer Care 800.222.7820
Custom Panels
For models 427G and 427RG, custom panels and handle
hardware must be installed. Stainless steel panels are
available through an authorized Sub-Zero dealer. For local
dealer information, visit the find a showroom section of our
website, subzero.com.
PANEL REQUIREMENTS
PANEL WEIGHT
Door
Drawer (427RG)
PANEL THICKNESS
All Panels
Reveals between panels can vary,
CAUTION
When using a panel thicker than
than
1
/
"
, panel may cause damage to the unit when
(6)
4
door is opened to 105°. Use the built-in 90° door stop.
CAUTION
As reveals between cabinetry and the unit decrease,
severe finger pinching can occur while door is closing.
Finish all sides of the custom panel. They may be visible
when the door is open or through the glass door.
D-style handles are recommended. Stainless steel tubular
and pro handles are avail able through an authorized
Sub-Zero dealer. For local dealer information, visit the find
a showroom section of our website, subzero.com. The door
handle must be located near the edge of the panel opposite
the hinge and should be centered top to bottom.
CAUTION
A solid panel cannot be installed over the glass door. A
solid door is available through an authorized Sub-Zero
dealer. For local dealer information, visit the find a
showroom section of our website, subzero.com.
MAX
20 lb
(9 kg)
12 lb
(5 kg)
MIN
5
/
"
(16)
8
1
/
"
reveals are typical.
(3)
8
3
/
"
with reveal less
(19)
4
Tabla de contenido