Generator Features - Powermate PM0145500 Manual Del Operador

Generador electrico
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

A. Control Panel
NOTE: Total power drawn from all receptacles must not exceed
the nameplate ratings.
B.
120 V, 20 Ampere Receptacle
20 amps of current may be drawn from the receptacle.
However, total power drawn must be kept within nameplate
ratings.
C. 120/240 V, 30 Ampere Twistlock Receptacle
Maximum full load current may be drawn from the
120/240 volt receptacle, provided it is the only receptacle
used. Total current must be limited to the nameplate
rating. If the 120/240 volt receptacle is used along with
the 120 volt receptacle, the total load drawn must not exceed the
nameplate ratings.
D. Circuit Protectors
The receptacles are protected by an AC circuit protector. If the
generator is overloaded or an external short circuit occurs, the circuit
protector will trip. If this occurs, disconnect all electrical loads and
try to determine the cause of the problem before attempting to use the
generator again. If overloading causes the circuit protector to trip,
reduce the load. NOTE: Continuous tripping of the circuit
protector may cause damage to generator or equipment. The cir-
cuit protector may be reset by pushing the button of the protector.
E.
Ground Terminal
F.
Air Filter
G. Engine On/Off Switch
H. 420 CC OHV Engine
I.
Recoil Starter
J.
Engine Choke Lever
K. Oil Filler Cap
L.
Oil Drain Plug
M. 7 Gallon Metal Fuel Tank
N. Fuel Tank Cap
O. Fuel Gauge
P.
Fuel Shut-Off Valve
English

GENERATOR FEATURES

GENERATOR FEATURES
Q. Multimeter
M
O
J
P
F
I
H
7
• When the generator is started, the voltage value is shown first.
• Press and release the mode button to toggle between Voltage,
Frequency, Total Hour Meter and Run/Maintenance
Timer.
• Voltage (V) displays the operating voltage of the generator.
• Frequency (F) displays the frequency in hertz at which the
generator is running.
• The Run/Maintenance Timer displays the time in hours and
minutes each time the generator is ran. The run timer resets
to 00:00 when the generator is shut off. Built into this run
timer is a maintenance reminder. When the new generator is
ran for 25 hours, the meter will display P25. This is to
remind you to change the oil after the initial 25 hours of run
time.
• When the Run/Maintenance Timer displays P50, it is
reminding you to clean the air filter.
• When the Run/Maintenance Timer displays P100, it is
reminding you to change/clean the fuel filter, clean the air
filter, and change the oil.
N
G
D Q
K
L
B
Customer Hotline 1-800-445-1805
D
C
E
A
Tabla de contenido
loading

Tabla de contenido