8. CONTROL PANEL • FUNCTIONS
POWER
By pressing the "POWER" button the dehumidifier turns on or off. The "Power" button and Display
will turn on.
• When the room's humidity level reaches 3% -5% below the desired set humidity
level, the device compressor will automatically stop, while the fan will continue to
operate. Continuous fan operation contributes to energy savings as the device
identifies the relative humidity of the area, allowing the compressor to operate much
less in a 24-hour period.
• In the event of a power failure the unit has an Auto Restart function. Once power
is restored, the appliance will automatically restart at the preselected settings prior
to the power failure.
MODE
By pressing the "MODE" button, various operations may be selected (Dryer, Cont., Smart).
While changing operation modes, device will make a short beep.
Dryer
Dryer mode: When this function is selected the device operates under Turbo Fan Speed.
After operating for approximately 2 hours the unit will check the room's humidity. If under
45%RH, only the fan will operate for two hours. After the 2 hours, the unit will quit dryer
mode. If over 45%RH, the unit will operate in Turbo fan Speed for 1 hour before checking the
room's humidity again. The maximum operation time set by this mode is 10 hours and can
be reduced depending on the room size and the dampness of the clothes.
• For drying clothes: place the dehumidifier in a small room and set nearby the
clothes rack. Keep doors shut and allow the dehumidifier to dry the clothes.
• For optimal results manual wringing of the clothes is suggested.
• Allow 30-50cm distance from the moist clothes.
Cont.
Continuous function: the dehumidifier operates continuously when the drainage pipe is
attached, or until the water tank is full, extracting humidity from the air. When this function is
active the indicator will turn on and the device will work constantly, disregarding the relative
humidity of the room and the desired humidity level set.
• For special humidity conditions where big amounts of condensation need to be
extracted, such as extremely moist rooms.
EN