How to Attach Drain Pan(Optional)
The air conditioner employs a proper drain method whereby the condensed water (moisture removed from the
air) is drained to the outside.
In very humid weather, (and for reverse cycle models in the reverse mode) excessive condensate water
removed from the air may cause some water to collect. To remove this excess water you can install the drain
pan as detailed below.
1. Take the drain pan which is located in the air discharge.
2. Remove the hole rubber from the base-pan (for some models).
3. Install the drain pan to the right corner of the cabinet with 4 (or 2)
screws.
4. Connect the drain hose of 3/5" inside diameter to the outlet located
at the bottom of the drain pan.You can purchase the drain hose or
tubing locally to satisfy your particular needs. (Drain hose is not
supplied).
How to Connect a Drain Hose
A drain hole is provided at the rear of the air conditioner unit.
Select a drain method according to the following.
1. Remove the hole rubber from the base-pan. (for some models)
2. Connect a drain hose of 9/16" inside diameter to the drain pipe as
shown in Fig. 1.
3. Or connect a pipe elbow of 9/16" inside diameter to the drain pipe,
then connect a drain hose of 9/16" inside diameter to the pipe
elbow as shown in Fig. 2.
Operating Instructions
CABINET
DRAIN
PAN
SCREW
DRAIN HOSE
DRAIN PIPE
DRAIN HOSE
DRAIN PIPE
DRAIN ELBOW
DRAIN HOSE
Owner's Manual 19
Fig. 1
Fig. 2