Programming - Rotex RKHBH008BB3V3 Manual De Funcionamiento

Ocultar thumbs Ver también para RKHBH008BB3V3:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 112

Programming

Programming space heating or domestic water heating
5 sec
5 sec
Operation manual
10
Programming space heating or domestic water heating is carried out
as follows:
Press the < button.
1
The actual mode is blinking.
Use the pi and pj buttons to select the mode you want
2
to program (space heating
Press the < button to confirm the selected mode.
3
The actual day is blinking.
4
Select the day you would like to consult or to program by means
of the pi and pj buttons.
The selected day is blinking.
Press the < button to confirm the selected day.
5
The first programmed action of the selected day appears.
Use the pi and pj buttons to consult the other
6
programmed actions of that day.
This is called the readout mode. Empty program actions (e.g. 3
and 4) are not displayed.
Press the < button for 5 seconds to enter the programming
7
mode.
Use the < button to select the action number you would like to
8
program or to modify.
Use the ba button to select:
9
■ For space heating:
■ For domestic water heating: use the ba button to enable or
5 sec
10 Use the pi and pj buttons to set the correct action time.
11 Repeat steps 8 to 10 to program the other actions of the
selected day.
When all actions have been programmed, make sure that the
display shows the highest action number you would like to save.
12 Press the < button for 5 seconds to store the programmed
actions.
If the < button is pressed when action number 3 is displayed,
actions 1, 2 and 3 are stored but 4 is deleted.
You automatically return to step 6.
By pressing the pr button several times, you return to previous
steps in this procedure and finally return to normal operation.
5 sec
INFORMATION
Returning to previous steps in the programming procedure
without saving modified settings is done by pressing the
pr button.
h
or domestic water heating
x: switch heating and the controller off.
-
9: set the temperature by means of the bi and
-
bj buttons.
a: to select automatic temperature calculation.
-
disable the x action.
Indoor unit and options for air to water heat pump system
w
)
RKHBH/X008BB
4PW62575-1 – 10.2010
Tabla de contenido
loading

Tabla de contenido