To protect the user from an electrical shock, the converter should be correctly connected to earth.
The converters are equipped with three cables (single phase) or four cables (three phase) and their
respective plugs. The adequate earth socket should be used to connect the converters. If the socket
with earth is not available, an earth adapter should be used before connecting the plugs.
Extension cables.
Always use extension cables with earth wire and its respective plug with earth in the female and
male plug.
Do not use damaged or worn out cables.
Avoid heavy loads on cables.
To determine the transversal section, follow the following procedure:
PROCEDURE TO DETERMINE THE NECESSARY TRANSVERSAL SECTION IN CABLE
EXTENSION
Do the following verifications and take the highest section of cable:
1. The ohmic resistance and inductive resistance of the cable with the permitted loss of voltage of
5%, cosphi=0.8 trough the frequency and voltage curve
Entering the curve with the product: Intensity x Length=10x100=1000 Am We obtain a 4 mm section
en
2. The permitted heating of the cable according to VDE standard ( minimum transversal section table
required).
Therefore, the section chosen is equal to 4 mm, Always choose the highest transversal section of
the two verifications
SECCIÓN DE LA LÍNEA EN mm
25
16
10
6
4
2,5
1,5
0
INTENSIDAD NOMINAL X LARGO DE LÍNEA (A m)
4.4

PETROL ENGIN

8
AFE - AFGH2000, AFGB2000, AFDY2000, AFDH4500, BOXEL
I.e:
Voltage nominal:........................... 1- 220 V 50 Hz
Nominal current:............................ 10 A
Cable length:................................. 100 m
I.e: For 10 A, according to table for 15 A or less, the section is of 1 mm.
2
115 V
230 V
1000
2000
3000
4000
Read the motor manufacturers' manual.
Do not work in rooms with scarce ventilation.
Make sure there is no flammable good near to the escape.
Check the petrol level in the reservoir.
Check the oil reservoir of the motor is full (see motors' manual) and the oil reservoir in the
vibrating group that also contains the exciter (10W 40 non faoming).
Secciones mínimas según normas VDE
Sección (mm
380 V
1
1,5
2,5
4
6
10
16
5000
6000
25
FRECUENCY CONVERTERS
2
) Carga máx. (A)
Fusible máx. (A)
15
18
10/3-16/1-
26
34
44
61
82
108
10
20
25
35
50
63
80