Monitor Adjustments - golmar PLATEA 90 Manual De Instalación

Monitor para reposición
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

MONITOR ADJUSTMENTS

H
andling the end of line jumper.
M
onitor(s) coding.
The SW2 configuration dip switch is placed on the monitor base.
Set the calling code on the monitor(s).
The addition of the assigned values to the switches 3 to 10 sets the monitor code;
if a switch is set to OFF position, its value will be zero.
Switch number:
ON value:
128
Locate the CN4 connector, that's placed in the monitor base.
Remove the existing jumper and plug the EL562 module.
NOTE: on this type of installations the emitter TXTP module must be
plugged in the 90 video door panel (see T86 manual), with Stadio
video door panel (
The end of line jumper is placed on the CN4 connector, that can be
located on the monitor base. In case of twisted pair cable
installations, the end of line jumper is placed in the EL562 module,
also located in the CN4 connector of the monitor base.
Do not remove the jumper on monitors where the video cable finish.
Remove the jumper on monitors where the video cable continue.
'Autoswitch-on' function (only in chalet installations).
If the door panel has been activated with the autoswitch-on
function, set in ON position the switch number 1 on the monitors
that wants to activate this function. If not, let it in the OFF position.
Set the monitors as master or slave.
Each apartment must have only one master monitor: set its switch
number 2 to OFF position. In case of monitors in parallel (slaves),
set their switch number 2 in ON position. The maximum number of
monitors in the same apartment are five.
3
4
5
6
7
64
32
16
8
E
l562 module for video installations
with twisted pair cable.
see the door panel manual
8
9
10
4
2
1
Example: 0+64+0+16+0+4+2+1=87
).