10
a
b
b
a
a. Wall attachment hole (x4).
b. Monitor attachment hook (x2).
c. Vertical wiring input.
d. Attachment clip.
e. Wiring input hole.
f. Installation terminals:
Terminals +, – , Malla (shield), VP and MP are duplicated for easiest daisy chain installation of
parallel monitors or telephones. If the first monitor is not placed on the connector, daisy chain
units will not be powered.
Installation:
Avoid to place the monitor near to heating sources, in dusty locations or smoky environments.
To install the monitor directly over the wall, drill two holes of 6mm. and use the supplied screws.
The upper part of the monitor connector must be placed at 1,60m. height roughly.
The minimum distance between the monitor connector and the closest object must be 5cm.
MONITOR CONNECTOR
50mm.
50mm.
Presionar para abrir.
Press to open.
Colocar la parte superior de la regleta a 1,60m. del suelo.
Place the top part of the monitor connector at 1,60m. from the floor.
11784095
CODE
REF
LOTE
RCPL-90
+, –:
positive, ground.
Vin :
video signal coaxial input.
Malla:
coaxial shield.
Vout :
video signal coaxial output.
:
microphone.
:
speaker.
HZ- :
door bell push button input.
SA :
auxiliary calling device output.
2C :
2nd camera activation output.
A1 :
optional device activation output.
Vp, Mp :
twisted pair video signal.
D
escription / installation of the RCPL-90
monitor connector.
V
in
Malla
Shield
Malla
Shield
V
out
HZ-
SA
2C
A1
VP
VP
MP
MP
c
d
e
f

Hide quick links: