Dyna-Glo WORKHORSE Serie Manual De Usuario E Instrucciones De Funcionamiento página 13

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
F.) SPARK PLUG
CLEAN AND REGAP EVERY 600 HOURS
OPERATION OR REPLACE AS NEEDED.
(For KFA50WH/80WH/135WH/180WH Models Only)
- Remove upper shell (See page 10).
- Remove fan (See page 10).
- Remove ignitor wire from spark plug.
- Remove spark plug from nozzle adaptor using medium
phillips screwdriver.
- Clean and regap spark plug electrodes to 3.5mm gap.
(0.138")
- Reinstall spark plug to nozzle adaptor.
- Attach ignitor wire to spark plug.
- Reinstall fan and upper shell.
(For KFA220WH Model Only)
- Remove upper shell (See page 10).
- Remove fan (See page 10).
- Remove ignitor wire from nozzle adaptor.
- Remove spark plug from nozzle adaptor using medium
phillips screwdriver.
- Clean and regap spark plug electrodes to 3.5mm gap.
(0.138")
- ReInstall spark plug to nozzle adaptor.
- Attach ignitor wire to spark plug.
- Reinstall fan and upper shell.
G.) PHOTOCELL
CLEAN PHOTOCELL ANNUALLY OR AS
NEEDED.
- Remove upper shell (See page 10).
- Remove fan (See page 10).
- Remove photocell from it's mounting.
Clean photocell lens with cotton swab.
TO REPLACE:
- Remove side cover screws using medium phillips
screwdriver.
- Disconnect switch wires from power switch and
remove side cover.
- Disconnect wires from circuit board and remove
photocell.
- Install new photocell and connect wires to circuit
board.
- Replace switch wires to power switch and side cover.
- Replace fan and upper shell.
Figure 16. Spark Plug Regap
Nozzle Adaptor
Ignitor Wire
Figure 17. Spark Plug Regap
Side Cover
Figure 18. Photocell Replacement
12
Spark Plug
Ignitor Wire
Nozzle Adaptor
Spark Plug
Screw
Spark Plug
Power
Switch
Screw
Photocell
Wire
Bracket
Install Photocell
Incorrect
Correct
Screw
Spark Plug
Switch
Wires
Photocell
Lens

Capítulos

Tabla de contenido
loading

Tabla de contenido