OPERATION
• Opens and closes automatically when hands are presented in the detection zone.
Comfort shut-off delay is 3 seconds.
TECHNICAL CHARATERISTICS
• Supply with cold water and hot water at 70°C maximum (we recommend 50°C to prevent the risk of scalding).
• This product has been designed to withstand both thermal and chemical shocks in line with current
regulations.
• Anti-blocking security: a timed shut-off ensures that the valve closes after 30 seconds of flow.
Once the object is removed the valve operation will reset automatically.
• Pressure: 1 - 5 bar (100 - 500kPa), we recommend 3 bar (300kPa).
Maximum pressure differential at the inlets: 1 bar.
MAINS SUPPLY MODELS
• Electrical supply: 100-240V / 50-60 Hz class II SELV (separated from earth) electrical supply.
The installation must conform to local Electrical Regulations/Standards and must be installed
by a competent, qualified electrician. A 30mA circuit breaker (not supplied) must be installed ahead
of the transformer. If the supply cable is damaged, it must be replaced by the installer.
• Shuts off automatically if the power supply fails.
• This equipment can be used by children aged 8 years old and over, people with reduced physical,
sensory or mental capabilities and people with a lack of experience or knowledge, if they are properly
supervised or if they have received instruction on how to use the equipment safely and if the associated
risks have been understood.
• Children should not play with the equipment. Cleaning and user maintenance should not be undertaken
by children without supervision.
• This equipment should only be used with the power supply provided by the manufacturer.
INSTALLATION
• To avoid interference from infrared beams do not install the electronic mixer or tap opposite a mirror
or shiny object. Do not install two electronic mixers or taps opposite each other.
• Under no circumstances should the non-return valves integrated in the water inlets
be removed (they are essential).
• Install the filters supplied exactly as shown in the diagrams. They protect the non-return valves
and keep them in place.
THE INSTALLER MUST ENSURE:
• THE SEAL AROUND THE RECESSING HOUSING IS WATERPROOF TO PREVENT ANY INGRESS
OF WATER;
• ANY WATER ACCIDENTALLY ENTERING THE RECESSING HOUSING (E.G. CONDENSATION, RUN
OFF, LEAKS, ETC.) HAS AN EXTERNAL DRAINAGE POINT TO PREVENT ANY STAGNATION;
• THE INTEGRITY OF THE SEALS BETWEEN THE STAINLESS STEEL WALL PLATE AND THE WALL
OR THE WALL PLATE AND THE MIXER/TAP/VALVE AT LEAST ONCE A YEAR, AND MAKE GOOD
IF NECESSARY.
If this advice is not followed, water may leak into the wall. DELABIE cannot be held
responsible for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL SUPPORT
UK: 01491 821821. ALL OTHER MARKETS: +33 (0)3 22 60 22 74.