Appendix C Technical Specifications
EN
grid
Continuous output power at 40 °C (P nom)
AC output current
AC output voltage (nominal)
AC output range
Protection
Standby losses
User interface
Connectivity
Backup switch over time
Solar
Max. Input
No. of strings
No. of MPP trackers
DC Disconnection switch
Solar Voltage
MPP Voltage
Solar Connections
Max. Efficiency
Max. MPP Efficiency
Environmental
Operating Temperature Range (full power)
Storage Temperature
Humidity
Regulatory Approvals and Standards
Safety
Emission
Immunity
Anti Islanding Protection
Warranty
general
Dimensions (WxHxD)
Protection Category
Weight
Topology
Cooling
16
PR50S/S0
PR37S/S0
5000 W (4600 W DE)
3700 W
22A
16A
230 Vac ± 2%, 50 Hz ± 0.2%, true sine wave <3% THD, single phase
180-264 Vac 45-55 Hz (limited by local anti-islanding regulations)
electronic, fused
≤ 6W
interactive display with 4-button operation
ethernet RJ45, TCP/IP
<1 second
PR50S/S0
PR37S/S0
5.5 kWp and 15 A per string
4 kWp and 15 A per string 3.3 kWp 15 A
2
2
2, fully independent
2, fully independent
4-pole, 600V, 15A
4-pole, 600V, 15A
150 – 600 Vdc per string
100 – 480 Vdc per string
MC4
94.5%
99.9%
PR50S/S0
PR37S/S0
-10 °C to +50 °C (derating from 40 °C)
-40 °C to +70 °C
maximum 95%, non-condensing
CE
EN 60950-1, EN 62109-1
EN 55014-1, EN 61000-3-2, EN 61000-3-3, EN 61000-6-3
EN 55014-2, EN 61000-6-2
VDE 0126.1.1, G83/1(UK), RD1663/2000(ESP), DK5940 E.d. 2.2 (IT),
AS4777(AUS) (check www.PowerRouter.com for other country certifications)
five years (optional: extension to ten years)
PR50S/S0
PR37S/S0
545 x 502 x 149 mm
IP 21
15.5 kg
galvanic isolated transformer
forced airflow
PR30S/S0
3000 W
13A
PR30S/S0
1
1
2-pole, 600V, 15A
PR30S/S0
PR30S/S0