Installation; Installing/Replacing The Lamp - EuroLite MIK UV Outdoor Spot Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

INSTALLATION

Installing/Replacing the lamp

For the installation, you need one of the following lamps, depending upon device version:
OMNILUX UV-Lamp 160W E-27
OMNILUX UV-Lamp 400W E-40
The lamp must only be changed when wearing appropriate protective clothing (protection glasses, protection
gloves, helmet with sight, leather apron).
UV illuminants are hazardous waste which needs to be disposed of appropriately.
Please dispose of the unusable UV illuminants in accordance with the current legal regulations.
The lamp life given by the manufacturer must never be exceeded. This is why you need to take notes on the
operational time of the lamp and replace the lamp in time.
Keep exchanged lamp in a protective container and remove accordingly.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 10 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
Procedure:
Step 1: Unscrew the cover screws.
Step 2: Remove the cover.
Step 3: If replacing the lamp, remove the old lamp from the lamp holder.
Step 4: Insert the lamp into the lamp holder.
Step 5: Replace the cover.
Step 6: Tighten the cover screws.
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
89513005
89514005
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened cover!
15/32
00025549.DOC, Version 1.2
Tabla de contenido
loading

Este manual también es adecuado para:

4000048040000485

Tabla de contenido