Caution: Devices in hanging installations may cause severe injuries when crashing down! If you have
doubts concerning the safety of a possible installation, do NOT install the device!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the device's
weight.
When installing the device, make sure there is no highly-inflammable
material (decoration articles, etc.) within a distance of min. 0.5 m.
Mount the device to your trussing system using an appropriate clamp.
For overhead use, always install a safety-rope that can hold at least 12 times the weight of the fixture. You
must only use safety-ropes with quick link with screw cap. Pull the safety-rope through the attachment eyelet
and over the trussing system or a safe fixation spot. Insert the end in the quick link and tighten the safety
screw.
The maximum drop distance must never exceed 20 cm.
A safety rope which already hold the strain of a crash or which is defective must not be used again.
Adjust the desired inclination-angle via the mounting-bracket and tighten the fixation screws.
Connect the fixture to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
Lighting effects must not be connected to dimming-packs.
Before taking into operation for the first time, the installation has to be approved by an expert!
The power supply of the ventilation-fans comes from the IEC-cable included in the delivery and must be
connected. Plug the IEC-cable into the IEC-socket on the rear panel. Plug the power plug into the power
outlet.
The power supply of the lamps comes from the 6-pin industrial plug. Connect your controller, e. g.
EUROLITE Mini 4-M or EUROLITE LCD-4 MP/S with the 6-pin industrial plug.
The occupation of the 6-pin industrial plug is as follows:
1. Channel 1
2. Channel 2
3. Channel 3
DANGER OF FIRE!
International
L
N
DANGER TO LIFE!
4. Channel 4
5. Neutral
6. Neutral