3. Proper use
The equipment you have purchased is designed
to pump water with a maximum temperature of
35 °C. This equipment must never be used for
other liquids, especially not for engine fuels,
cleaning agents and other chemically-based
products!
The equipment can be used wherever you want to
move water, e.g. in the house, in the garden, and
for many other applications. It must not be used to
operate swimming pools!
If you want to use the equipment in bodies of wa-
ter with a natural, muddy bottom, place the equip-
ment in a slightly elevated position, e.g. on bricks.
The equipment is not designed for continuous
operation, e.g. as a circulating pump in a pond. In
this case the equipment's anticipated life will be
greatly shortened because the equipment was
not designed for continuous loading.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
The water may be contaminated by escaping lub-
ricating oil/lubricant.
Anl_GC_DW_1300_N_SPK9.indb 17
Anl_GC_DW_1300_N_SPK9.indb 17
GB
4. Technical data
Mains connection ......................... 230 V ~ 50 Hz
Power consumption ................................ 1300 W
Max. pumping rate ..................................5000 l/h
Max. delivery head ...................................... 65 m
Max. immersion depth ................................. 20 m
Water temperature max. ............................. 35°C
Hose connection .................................................
................ approx. 47.8 mm (1 1/2") female thread
Max. size of foreign bodies: .............. Clean water
Protection type: ............................................IPX8
Power cable .................................................. 2 m
Pump line .................................................... 23 m
5. Before starting the equipment
Before you connect the equipment to the mains
supply make sure that the data on the rating plate
are identical to the mains data.
5.1 Installation
The equipment can be installed either:
•
Stationary with a rigid pipe line
or
•
Stationary with a flexible hose line
•
Connect the pressure hose or pipe to the
pressure connector (3) using a suitable con-
nector.
•
The equipment must be fastened with the
supplied rope (Fig. 1/Item 10) to the suspen-
sion eyes (Fig. 3/Item A).
Notice!
Before you use the pump, clarify any possible
special conditions which need to be fulfi lled for
the installation!
For example, additional safety measures may be
needed if damage to property could result from a
power failure, soiling or a defective gasket.
Examples of such safety measures:
Pumps running in parallel on a separately protec-
ted power circuit, moisture sensors for switching
off the pumps, and similar safety arrangements.
Be sure to consult a professional plumber if you
have any doubt.
The maximum pumping rate is possible only with
the largest possible line diameter; if smaller hoses
or pipes are connected, the pumping rate will be
reduced.
- 17 -
26.04.2019 09:03:54
26.04.2019 09:03:54