SN2013/IR, SN2033/IR
4
Connect Drain
Off-Line Vent (Type A or O): Connect 1-1/2" P-Trap and
drain piping (supplied by installer) to the drain spud .
Centrally Rising Vent (Type B or H) or models with
optional paper towel dispensers: Connect the vented
P-Trap (provided) and drain piping as shown .
5
Turn on Water and Electricity, Test and Adjust Unit
Check to make sure stop valves
are open before turning on water.
Turn on power to transformer . Turn on
A
water supply and check for leaks . Activate
each IR sensor to purge air from the lines .
This valve is NOT factory preset.
Upon installation, the temperature
of this valve must be checked and
adjusted to ensure delivery of a safe
water temperature. Water in excess
of 110°F (43°C) may cause scalding.
8
8/15/2014
Strainer
Drain Spud
Tailpiece
P-Trap
Loosen the cap screw about
B
¼" (4–6 turns) and lift up
the cover (do not remove) .
Using the cover, turn
the cartridge gently until
desired water temperature
C
is reached . Do not turn past
stops as this may damage
the unit . Push the cover
down and tighten the screw .