Wiring
21
22
23
24
25
26
* I max. < 10 A / III
FM
C-6
C-10
N S
R T
POWER SUPPLY
INPUT
400 V ±10%
50 Hz ±5 Hz
ATTENTION: Make sure to turn of the equipment's power supply before handling it, as different areas
may be energised.
IMPORTANT
The recommended currents and powers are the maximum working currents and powers.
Ÿ
The function of each probe depends on the "probe setting" parameter (See page 25).
Ÿ
Remember that the control probe and registration probe should be configured separately if you
Ÿ
want to comply with EN12830.
The function of the digital inputs depends on the configuration.
Ÿ
The AUXILIARY relay is programmable, and its operations depends on the configuration.
Ÿ
27
28
29
30
31
32
MODBUS
ALARM
RS-485
RELAY
F1
K1
N
U V W
PE
DEFROST
RESISTANCE
5500 W
400 V~ / III*
33
34
35
36
37
38
L N
FAN
230Vac
475 W
N L
SOLENOID
230Vac
2 A
20
* I max. < 6 A
39
40
41
42
43
N L
LIGHT
230Vac
460W
L
N
AUX.
AUXILIARY
RELAY
1
1
The auxiliary relay output
function (terminals 40
and 41) is configurable.