Gas Conversion - Dyna-Glo BF10DTL-4 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

INSTALLATION
GAS SELECTION
CAUTION: The knob to the gas selection means shall not be accessed or adjusted while the
appliance is in operation.
WARNING: Gas selection should only be done by a qualified technician.
WARNING: The unused regulator must be fitted with a metal plug with a pipe thread sealant.
WARNING: Failure to plug the unused regulator may result in a fire, property damage, personal
injury, or death.
Units to be used with LP
Remove the plug from the inlet of the LP regulator; do not make any further adjustments. Proceed to
installing the gas line as instructed in the Owner's Manual.
LP TO NG Conversion
1. Before gas conversion, remove screws and access panel for selector valve.
2. The gas selector valve should be in the LP position. Push and turn the selector knob
clockwise
until the knob locks into the NG position (See Fig. 4a). The selector valve must
be locked in the NG position. DO NOT operate the heater between the locked positions.
3. Remove plug from the inlet of the NG regulator.
4. If the LP plug was removed previously, apply thread sealant to ensure that there are no leaks
and install the NG plug into the inlet of the LP regulator and tighten firmly. (See Fig 5a and 5b).
5. Replace selector valve access panel.
Fig. 4a - Selector Valve Positioning
NG TO LP CONVERSION
1. Before gas conversion, remove screws and access panel for selector valve.
2. The gas selector valve should be in the NG position. Push and turn the selector knob counter
clockwise
until the knob locks into the LP position (See Fig. 4b). The selector valve
must be locked in the LP position. DO NOT operate the heater between the locked positions.
3. Remove plug from the inlet of the LP regulator.
4. Using thread sealant to ensure there are no leaks, replace plug into the inlet of the NG regulator
and tighten firmly (See Fig. 5b).
5. Replace selector valve access panel.
Fig. 4b - Selector Valve Positioning
Selector
LP
Valve
NG
Selector
LP
Valve
NG
11
Fig. 5a - Regulator Plug Location
Natural
Propane
Gas
Fig. 5b - Regulator Plug Location
Natural
Propane
Gas
Plug This
Plug This

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Bf20dtl-4Bf30dtl-4