TEST AND ADJUSTMENT
❒ Turn on the circuit breaker and light switch.
NOTE: Sensor has about 1
before it will detect motion. When first turned
on, wait about 1
❒ Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.
ON-TIME
10 5 1 TEST
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
Maximum Range
The detector is most sensitive to motion across its field
of view.
Motion
Sensor
Least Sensitive
598-1120-04
/
minutes warm up period
1
2
/
minutes.
1
2
RANGE
MIN
MAX
70 ft.
(21 m)
Maximum
Coverage Angle
Motion
Most Sensitive
❒ Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
❒ Walk through the coverage area
noting where you are when the
lights turn on (also, the LED will
flash several times when motion
is detected). Move the sensor
head up, down, or sideways
to change the coverage area.
Keep the sensor at least
1" (2.5 cm) away from the
lamps.
❒ Adjust the RANGE as needed.
RANGE set too high may
increase false triggering.
❒ Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
❒ Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 10 minutes).
Note: One minute mode is not recommended for
use with compact fluorescent bulbs.
Warning - Risk of fire. Do not aim the lamps at a
combustible surface within 3 ft. (1 m).
SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
Sensing Angle . . . . . . Up to 180°
180°
Electrical Load . . . . . . Up to 120 Watts Maximum
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.
3
Clamp
Screw
Ball
Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
surrounding temperature].
Incandescent [Up to 60 Watts
Maximum each lamp holder.]
Up to 40 Watts Maximum
Fluorescent [Up to 20 Watts
Maximum each lamp holder.]
MODE