PowerBoss 01648-1 Instrucciones De Uso página 10

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983
PowerBOSS™
• DO NOT connect 50 Hz loads to the generator.
• DO NOT OVERLOAD THE GENERATOR. See
"Don't Overload Generator".
Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected to it.
• See "Don't Overload Generator".
• Start generator and let engine stabilize before connecting
electrical loads.
• Connect electrical loads in OFF position, then turn ON for
operation.
• Turn electrical loads OFF and disconnect from generator
before stopping generator.
Stopping the Engine
1.
Turn OFF and unplug all electrical loads from generator
panel receptacles. NEVER start or stop engine with
electrical devices plugged in and turned ON.
2.
Move idle control switch to "Off" position.
3.
Let engine run at no-load for several minutes to
stabilize internal temperatures of engine and generator.
4.
Turn engine off according to instructions given in the
engine operator's manual.
5.
Move both fuel valves to "Off" position.
Operating Automatic Idle Control
This switch is designed to greatly improve fuel economy.
When this switch is turned ON, the engine will only
run at its normal high governed engine speed when an
electrical load is connected.When an electrical load is
removed, the engine will run at a reduced speed. With the
switch off, the engine will run at the normal high engine
speed. Always have the switch off when starting and
stopping the engine.
Charging a Battery
Your generator has the capability of recharging a discharged
12 Volt automotive or utility style storage battery.
• DO NOT use the unit to charge any 6 Volt batteries.
• DO NOT use the unit to crank an engine having a
discharged battery.
4500W Portable Generator
CAUTION
www.mymowerparts.com
DANGER
Storage batteries give off explosive hydrogen gas
during recharging.
Hydrogen gas stays near battery for a long time
after battery has been charged.
Slightest spark will ignite hydrogen and cause
explosion.
You can be blinded or severely injured.
Battery electrolyte fluid contains acid and is
extremely caustic.
Contact with battery fluid will cause severe
chemical burns.
• DO NOT allow any open flame, spark, heat, or lit cigarette
during and for several minutes after charging a battery.
• Wear protective goggles, rubber apron, and rubber gloves.
To recharge 12 Volt batteries, proceed as follows:
1.
Check fluid level in all battery cells. If necessary, add
ONLY distilled water to cover separators in battery
cells. DO NOT use tap water.
2.
If battery is equipped with vent caps, make sure they
are installed and are tight.
3.
If necessary, clean battery terminals.
4.
Connect battery charge cable connector plug to panel
receptacle identified by the words "12-VOLTS D.C.".
5.
Connect battery charge cable clamp with red handle
to the positive (+) battery terminal (Figure 6).
Figure 6 — Battery Connections
6.
Connect battery charge cable clamp with black handle
to the negative (–) battery terminal (Figure 6).
7.
Start engine. Let engine run while battery recharges.
8.
When battery has charged, shut down engine
10