Some dust created by power sanding, sawing, grinding, drilling, and other
construction activities contains chemicals known to cause cancer, birth defects
or other reproductive harm. Some examples of these chemicals are:
• lead from lead-based paints,
• crystalline silica from bricks and cement
and other masonry products, and
• arsenic and chromium from chemically-treated lumber.
Your risk from these exposures varies, depending on how often you do this
type of work. To reduce your exposure to these chemicals: work in a well
ventilated area, and work with approved safety equipment, such as those
dust masks that are specially designed to filter out microscopic particles.
ADVERTENCIA
Se sabe que el polvo generado por el lijado, la aserradura, el esmerilado, la
perforación mecánica y por otras actividades de construcción contiene químicos
que producen cáncer, malformaciones congénitas u otros daños relacionados
con la reproducción. Algunos ejemplos de estos químicos son:
• Plomo de pintura a base de plomo,
• Sílice cristalina de ladrillos y cementos y otros productos de mampostería, y
• Arsénico y cromo de maderas tratadas químicamente.
El riesgo ante estas exposiciones varía, dependiendo de cuan frecuente usted
haga este tipo de trabajo. Para reducir la exposición a estos químicos: trabaje
en espacios bien ventilados, y trabaje con equipos de seguridad aprobados,
tales como las mascarillas contra el polvo diseñadas específicamente para
detener partículas microscópicas.
1/2" DR.
HEAVY DUTY
IMPACT WRENCH
with 2" Extended Anvil
Llave de impacto con agujero de torsión de 13 mm
para uso pesado y con yunque extendido de 5 cm
THIS INSTRUCTION MANUAL
CONTAINS IMPORTANT
SAFETY INFORMATION
READ CAREFULLY AND
UNDERSTAND ALL
INFORMATION BEFORE
OPERATING THIS TOOL!
SAVE THIS MANUAL
FOR FUTURE REFERENCE.
LAS INSTRUCCIONES
EN ESPAÑOL COMIENZAN
EN LA PÁGINA # 7.
ESTE MANUAL DE
INSTRUCCIONES CONTIENE
IMPORTANTES INFORMACIONES
¡LEA CUIDADOSAMENTE
Y ASEGÚRESE DE COMPRENDER
TODAS ESTAS INFORMACIONES,
ANTES DE PROCEDER CON
EL FUNCIONAMIENTO DE
ESTA HERRAMIENTA!
CONSERVE ESTE MANUAL
PARA TENER UNA
REFERENCIA EVENTUAL.
6-745A
DE SEGURIDAD
Tabla de contenido
loading

Resumen de contenidos para Napa 6-745A

  • Página 1 ESTA HERRAMIENTA! 1/2" DR. HEAVY DUTY CONSERVE ESTE MANUAL PARA TENER UNA IMPACT WRENCH REFERENCIA EVENTUAL. with 2” Extended Anvil 6-745A Llave de impacto con agujero de torsión de 13 mm para uso pesado y con yunque extendido de 5 cm...
  • Página 2 • Operators and maintenance personnel surface. must be physically able to handle the • Use accessories recommended by NAPA bulk, weight and power of this tool. • Keep body working stance balanced Professional Air Tools. and firm. Do not overreach when operating the tool.
  • Página 3: Air Supply

    PROFESSIONAL AIR TOOL Service Centers. This warranty does not cover damage to tools rising from alteration, abuse, misuse and does not cover any repairs made by anyone other than an authorized NAPA PROFESSIONAL AIR TOOL Warranty Center. Tools sent to a Warranty Center in a dissembled condition will not be covered as a warranty repair.
  • Página 4 Length ........... 9.06" Air Inlet Thread ...... 1/4" NPT Avg. Air Consumption .... 5.0 CFM Rec. Air Pressure ......90 psig Air Regulator Air Inlet PLEASE REVIEW ALL WARNING INSTRUCTIONS PRIOR TO OPERATION. SAVE THIS MANUAL FOR FUTURE REFERENCE. 6-745A Rev. 05/27/05...
  • Página 5: Parts Breakdown

    PARTS BREAKDOWN 6-745A PARTS LIST Index # Part # Description Qty. Index # Part # Description Qty. RS186001 Housing (incl. #2) RS95922 Front Dowel Pin Valve Sleeve (incl. w/#1) RS360E23 Cylinder RS186003 Reverse Valve RS95924 RS26058 O-Ring RS360E25 Rear End Plate...
  • Página 6 PLEASE REVIEW ALL WARNING INSTRUCTIONS PRIOR TO OPERATION. SAVE THIS MANUAL FOR FUTURE REFERENCE. 6-745A Rev. 05/27/05...
  • Página 7: Al No Seguir Todas Instrucciones De La Lista Abajo Puede Provocar Lesiones Graves

    • Utilice los accesorios recomendadas por hacia otras personas. Cierre funcionamiento de la herramienta. Napa Professional Air Tools. siempre el abastecimiento REVISE TODAS LAS INFORMACIONES DE ADVERTENCIA, ANTES DE PROCEDER CON EL FUNCIONAMIENTO. CONSERVE ESTE MANUAL PARA TENER UNA REFERENCIA EVENTUAL.
  • Página 8: Abastecimiento Del Aire

    Puede echar el SOLAMENTE para añadir aceite aceite dentro de la entrada del estandar SAE 10 o 20 después REVISE TODAS LAS INFORMACIONES DE ADVERTENCIA, ANTES DE PROCEDER CON EL FUNCIONAMIENTO. CONSERVE ESTE MANUAL PARA TENER UNA REFERENCIA EVENTUAL. 6-745A Rev. 05/27/05...
  • Página 9: Funcionamiento

    Consumo mediano de aire ..5.0 CFM Entrada del Regulador del aire Presión del aire ......90 psig aire REVISE TODAS LAS INFORMACIONES DE ADVERTENCIA, ANTES DE PROCEDER CON EL FUNCIONAMIENTO. CONSERVE ESTE MANUAL PARA TENER UNA REFERENCIA EVENTUAL. 6-745A Rev. 05/27/05...
  • Página 10: Problemas Y Soluciones

    El exceso está para quitarlo fuera de la ranura. Quite DEBE: Verifique la entrada del aire normalmente propulsado hacia REVISE TODAS LAS INFORMACIONES DE ADVERTENCIA, ANTES DE PROCEDER CON EL FUNCIONAMIENTO. CONSERVE ESTE MANUAL PARA TENER UNA REFERENCIA EVENTUAL. 6-745A Rev. 05/27/05...
  • Página 11 (1) año. Todas las herramientas NAPA PROFESSIONAL AIR TOOLS deben ser reparadas solamente en centros de servicio autorizados NAPA PROFESSIONAL AIR TOOLS. Esta garantía no cubre los daños a las herramientas provocados por modificaciones, abuso, utilización mala y no cubre reparaciones ejecutadas por cualquier centro de reparaciones que no sea une centro autorizado de garantía NAPA PROFESSIONAL...