Operation

AC/DC Current Measurements

WARNINGS:
Disconnect the test leads and temperature probe from the
meter before making current clamp measurements. Do not measure current on
conductors that are more than 600V above earth ground if in a CAT IV application or
more than 1000V above earth ground if in a CAT lll application.
Observe safety precautions when working on live circuits.
1. Set the rotary function switch to the 600A or 1000A position.
2. If the range is not known, select the higher range first, and then move to
the lower range if necessary.
3. Select AC (~) or DC ( ) by pressing the MODE
button. In the DC mode, allow time for the
meter to Zero before taking a measurement.
If necessary, press the REL button to Zero
out any DC offset. Zeroing the meter is not
necessary when measuring AC current.
4. Press the trigger to open the jaw. Clamp around a single conductor making
sure the jaws are fully closed before taking a measurement.
For best results, keep the conductor centered inside the jaw.
5. Read the current on the LCD display.
NO
Incorrect
Non-Contact
Voltage Detector
1000A
600A
AUTO
POWER
OFF
MAX
MODE
REL
MIN
23070T
AC/DC TRMS CLAMP METER
CAT IV 600V
CAT III 1000V
YES
Correct
9
Operation cont.
AC Voltage Measurements
WARNING:
Observe all safety precautions
when working on live voltages.
1. Set the rotary function switch
to the V~ position.
2. Insert the black test lead into the
COM input jack and the red test
lead into the V input jack.
3. Touch the test lead probes to the
circuit under test.
4. Read the voltage on the LCD display.

DC Voltage Measurements

WARNING:
Observe all safety precautions
when working on live voltages.
1. Set the rotary function switch
to the V
position.
2. Insert the black test lead into the
COM input jack and the red test
lead into the V input jack.
3. Touch the test lead probes to the
circuit under test. Touch the red
test lead to the positive side of the
circuit and the black test lead to
the negative side of the circuit.
4. Read the voltage on the LCD display.