SATURN - BOXER MOTOR REDUCERS USING GRAPHIC
2000 kg
1500 kg
1200 kg
1000 kg
600 kg
500 kg
Motor reducers
20%
25%
30%
35%
40%
55%
60%
DIMENSIONS (mm)
320
1. GATE ARRANGEMENT
Before starting with the installation check if all the gate parts
(fixed and mobile) have a strong and as less as possible
deformable structure, also make sure that :
a) The leaf is rigid and compact;
b) The inferior slideway is perfectly straight, horizontal and
without any obstacles which could obstruct the gate sliding;
c) The inferior sliding wheels are equipped with greasable or
water tightened bearings;
d) The superior slideway has been produced and placed so that
the gate is in a perfect vertical position;
e) Mechanical stops of the leaf are always installed in order to
avoid possible derailment of it.
10
®
2. FOUNDATION PLATE ANCHORAGE
To install the foundation plate it is necessary to:
2.1. Prepare a concret basement with the dimensions shown in
Fig. 1 where the foundation plate and the anchor bolts will be
concreted.
NOTE: It is recommended, gate structure permitting, to lift the
foundation plate about 50mm from the ground, in order to avoid
eventual water stagnation.
Fig. 1
2.2.
Before cementing the plate insert a flexible plastic duct of at
least 30mm in diameter into the special hole of the plate.
2.3. Before concreting in the plate, make sure that it is perfelcty
leveled and that the distance of 58-67 mm as shown in Fig. 2 is
respected.
58-67
3. CABLES PASSAGE ARRANGEMENT
Saturn and Boxer are provided with two different holes for
electric cables passage.
It's very important to make the low - tension 230V~ cables pass
through one hole and and the very low safety tension cables
24V through the other one (Fig. 3)
ENGLISH
DIMENSIONS (mm)
MINIMUN DIMENSION Q
108 mm
Z16
116 mm
Z20
43-58
Plinto
Fig. 2