GUIDELINES FOR EXTENSION CORDS
Make sure the extension cord is in good shape. When using an
extension cord, verify the gauge is enough for the power that your
product needs. A lower gauge cord will cause voltage drop in the
line, resulting in power loss and overheating.
The following table shows the right size to use depending on the
cord´s length and the ampere capability shown in the tool's
nameplate. If in doubt, use the next higher gauge. The lower the
gauge, the heavier the cord will be.
Make sure that your extension cord is properly grounded and in
good shape.
(1) It is safe to use only if the extensions themselves have an artifact for over current protection.
(2) One of the conductors should be grounded. All conductors are the same gauge including the one that is grounded.
Reference: NMX-J-195-ANCE-2006

TROUBLESHOOTING

PROBLEM
The motor does not start.
The motor runs without
pumping water.
Flow speed is not enough.
The motor overload short
is activated
In case the problem can not be solved please go to an Authorized Service Center.
Failure to follow with these caution advices may damage the pump and void the warranty.
CONCRETE BASE
RIGHT INSTALLATION
CAUSE
- There is no energy.
- Blocked impeller.
- Clogged filter.
- Excessive height in the suction.
- Air in the admission.
- Suction height is in the limit.
- Filter is partially clogged.
- Blocked impeller.
- Motor overload.
- Stuck impeller.
JOINER NUT
SUCTION PIPING
SUPPORT
MINIMUM LEVEL
19.6"
FOOT VALVE
SAND BOX
ELECTRIC DIAGRAM
Ampere Capacity
Higher than
Up to
0 A
10 A
10 A
13 A
13 A
15 A
15 A
20 A
SOLUTIONS
- Check the connections and the power values
- See the maintenance section
- Clean the filter
- Reduce the suction pipe length.
- Double-check the suction pipe is hermetic.
- Check the foot valve is submerged at least 19.6"
- Priming the pump back is required.
- Verify the suction height.
- Shorten the suction pipe length.
- Clean the foot valve and the whole suction pipe is necessary.
- Release the impeller (See maintenance section)
- Double-check power and ventilation.
- Release the impeller ( see the maintenance section)
INSTALLATION
WRONG INSTALLATION
R
(2)
Extension Gauge
Number of
From 5.9' to
Higher than 49.2'
Conductor
49.2'
3
18 AWG (1)
3
16 AWG
3
14 AWG
3
8 AWG
REGULATE VALVE
16 AWG
14 AWG
12 AWG
6 AWG
4
Tabla de contenido
loading

Este manual también es adecuado para:

Boap-3/4aBoap-1a157591575815757

Tabla de contenido