1.Technical Data

Bore & stroke
Power
Model
1
2
[inch]
[Joule]
[mm]
max. pressure 6.3bar(90psi)
a
: Vibration level, k Uncertainty ; L
h
Declaration of noise and vibration statement (ISO 15744 and ISO 28927-10)
All values are current as of the date of this publication. For the latest information please visit www.cp.com.
These declared values were obtained by laboratory type testing in accordance with the stated standards and are suitable for comparison with the declared
values of other tools tested in accordance with the same standards. These declared values are not adequate for use in risk assessments and values measured
in individual work places may be higher. The actual exposure values and risk of harm experienced by an individual user are unique and depend upon the way
the user works, the workpiece and the workstation design, as well upon the exposure time and the physical condition of the user. We, CHICAGO PNEUMATIC
TOOLS , cannot be held liable for the consequences of using the declared values, instead of values refl ecting the actual exposure, in an individual risk
assessment in a work place situation over which we have no control. This tool may cause hand-arm vibration syndrome if its use is not adequately managed.
An EU guide to managing hand-arm vibration can be found at www. pneurop.eu/uploads/documents/pdf/PN3-02-NV_Declaration_info_sheet_0111.pdf. We
recommend a programme of health surveillance to detect early symptoms which may relate to noise or vibration exposure, so that management procedures can
be modifi ed to help prevent future impairment.
2. Machine type(s)
• This product is designed for removing material using a chisel or suitable needles. No other use permitted. For professional use only.
• Please read the instructions carefully before starting the machine.
3. Operation
• Fix the accessories properly to the tool.
• Connect device as shown in Fig. 01.
• To start the machine, pull the trigger (A). Machine speed is increase by increasing pressure on the trigger. Release the trigger to stop.
• Remember that it is always the tool that must do the work. There is no need for the operator to apply extra pressure on the tool when it is working. Maintain
the contact with the work surface by applying enough pressure to stop the tool from bouncing.
4. Lubrifi cation
Use an air line lubricator with SAE #10 oil, adjusted to two drops per minute. If an air line lubricator cannot be used, add air motor oil to the inlet once a day.
Recommended lubricant :
CP Oil PROTECTO-LUBE
- 4 oz (0.12l) P/N: CA149661
- 20.8 oz (0.591l) P/N: CA000046
- 1gal (3.8l) P/N: P089507
5. Maintenance instruction
• Follow local country environmental regulations for safe handling and disposal of all components.
• Maintenance and repair work must be carried out by qualified personnel using only original spare parts. Contact the manufacturer or your nearest authorised
dealer for advice on technical service or if you require spare parts.
• Always ensure that the machine is disconnected from energy source to avoid accidental operation.
• Disassemble and inspect the tool every three 3 months if the tool is used every day. Replace damaged or worn parts.
• High wear parts are underlined in the parts list.
6. Disposal
• The disposal of this equipment must follow the legislation of the respective country.
• All damaged, badly worn or improperly functioning devices MUST BE TAKEN OUT OF OPERATION.
• Repair only by technical maintenance staff.
7. Declaration of conformity
We :
CHICAGO PNEUMATIC Tool Co. LLC 1800 Overview Drive Rock Hill, SC 29730 - USA
Machine type(s):
Air Hammer
CP7111 & CP7150
Declare that the product(s):
Taïwan
Origin of the product :
is in conformity with the requirements of the council Directives on the approximation of the laws of the Member States relating : to "Machinery"
applicable harmonised standard(s) :
:Nicolas Lebreton (R&D Manager)
Name and position of issuer
Place & Date :
Saint-Herblain, 04/06/2015
Technical fi le available from EU headquarter. Nicolas Lebreton R&D manager CP Technocenter 38, rue Bobby Sands - BP10273 44800 Saint Herblain - France
Original Instructions are in English. Other languages are a translation of the original instructions.
Copyright 2015, Chicago Pneumatic Tool Co. LLC
All rights reserved. Any unauthorized use or copying of the contents or part thereof is prohibited. This applies in particular to trademarks, model denominations, part numbers and drawings.
Use only authorized parts. Any damage or malfunction caused by the use of unauthorized parts is not covered by Warranty or Product Liability.
Blows per
Dimension
Weight
minute
L
H
W
L
3
4
[inch]
[mm]
Sound pressure dB(A), K
pA
pA
From 0000001 to 9999999
Serial Number:
EN ISO 11148-4:2012
Air Consumption
Air Inlet
Average
at load
5
6
7
[kg]
[l/min]
[l/min]
[inch]
[lb]
[SCFM]
[SCFM]
= K
= 3 dB Uncertainty.
WA
Sound pressure
Soundpower
Inner Hose
Dia.
L
pA
8
9
[inch]
[dB(A)]
[dB(A)]
[mm]
2006/42/EC (17/05/2006)
Vibrations
L
a
K
wA
hd
10
11
[m/s²] [m/s²]