User Guide Fleck 5810-XTR
Day and time screen
day of week
Press the
,
the values to the correct day of week and time. Setting the value of the
PM/HR
button to HR changes the display to a 24 hour clock. Press the
month
year
, and
buttons to adjust the values to the correct date. Press
when finished to return to the home screen. Press
screen without saving.
Settings screen
Press
to access the settings screen. Press
to adjust the number of days since last regeneration in which a new
regeneration will automatically be run whether one is scheduled or not. Press
regen. time
to adjust the time of day that an automatic regeneration cycle
will begin.
hardness
Press
to adjust the hardness setting. This value should match the
hardness of the incoming untreated water supply. Press
changes or press
to return to the home screen.
Note:
Changing the hardness setting recalculates treatment
volume and regeneration interval.
4.2.
Diagnostic mode
Press
from the home screens to view the diagnostic screen. Press the screen navigation arrows at the upper-right and left
of the screen to view each diagnostic parameter. Press
5 .
Operation
5.1.
Recommendations
• Use only regenerate salts designed for water softening EN973;
• for optimal system operation, the use of clean salt free from impurities is recommended (for example salt pellets);
• do not use ice melt, block, or rock salts;
• the sanitizing process (both with liquid and electrochlorination) introduces chlorine elements which may reduce the lifetime
of the ion exchange resins. Refer to the technical guides for resins in common use, providing necessary checks on the
system.
5.2.
Manual immediate regeneration
Press
to move to the regeneration screen.
now
Press
to begin a regeneration immediately, or press
queue the regeneration for the programmed regeneration time. Pressing
regen. time
again will cancel the manual regeneration.
During regeneration, press
Once in regeneration, the volume or time will be displayed below
8 / 52
hour
minute
AM/PM/HR
,
, and
day override/time-driven
to immediately advance to the next cycle step.
buttons to adjust
AM/
day
,
to return to the home
to save your
to return to the home screen.
at regen. time
to
at
.
Day And Time
17
jan
15
sat
12
01
pm
Settings
day override/
time-driven
regen. time
02:00 am
hardness
300 mg/L
Regeneration
now
at regen. time
Ref. MKT-UG-018 / B - 16.01.2018
off